Fault_msg_power_too_high – 103h, Cause, Solution – ThingMagic M5e-Compact User Manual
Page 213: Fault_msg_invalid_freq_received - 104h, Fault_msg_invalid_parameter_value - 105h

Common Error Messages
Appendix C: Error Messages
213
FAULT_MSG_POWER_TOO_HIGH – 103h
Cause
A message was sent to set the read or write power to a level that is higher than the
current HW supports.
Solution
Check the HW specifications for the supported powers and insure that the level is not
exceeded.
The M5e 1 Watt units support power from 5 dBm to 30 dBm.
The M5e-Compact units support power from 10 dBm to 23 dBm.
FAULT_MSG_INVALID_FREQ_RECEIVED - 104h
Cause
A message was received by the reader to set the frequency outside the supported range
Solution
Make sure the host does not set the frequency outside this range or any other locally
supported ranges.
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
Cause
The reader received a valid command with an unsupported or invalid value within this
command.
For example, currently the module supports two antennas, 1 and 2. If the module
receives a message with an antenna value other than 1 or 2, it returns this error.
Solution
Make sure the host sets all the values in a command according to the values published in
this document.