Application Tag Commands
Command Set
137
Calibrate
The NXP command Calibrate causes the tag to return a random data pattern that is
useful in some frequency spectrum measurements.
Calibrate can only be sent when the tag is in the Secured state, when the access
password is non-zero. This command uses only the common fields and is invoked with
the following command.
The response to the Calibrate command contains 64 bytes of Calibrate Data, only if
Status=0x0000. The format of the response is:
Calibrate embedded in a Read Tag Multiple take the following form:
Note
If the tag is a G2XL without User Memory the
Calibrate Data
response field
will contain 64 bytes of ‘00’.
NXP G2i* Silicon (Chip Type=0x07)
Tags using the NXP G2i Silicon (SL3S1203_1213), please contact NXP for further details,
support all the commands defined for
NXP G2X* Silicon (Chip Type=0x02)
, with the
caveats as noted in the command descriptions. In addition the following custom
commands is G2i* only.
FF
10
2D
03
E8
02
44
00 05
00
00
00
78
08
34
11
22
33
44
??
??
SOH
Length
OpCode
Timeout (ms)
Chip
Type
Option
Sub
Cmd
Select Data Address
Select
Length
Selct
Data
Access Password
CRC
FF
09
2D
00
00
02
44
00 05
[64 bytes]
??
??
SOH
Length
OpCode
Status
Chip
Type
Option
Sub
Cmd
[Calibrate
Data]
CRC
FF
19
22
04
00
04
03
E8
11
22
33
44
00
00
00
78
08
34
SOH
Length
OpCode
Options
(EPC Mem)
Search
Flags
Timeout
Access Password
Select Data Address
(bits)
Select
Data
Length
(bits)
Select
Data
01
0A
2D
00
00
02
40
00
05
11
22
33
44
??
??
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
Embd Cmd
Timeout
(Not Used)
Chip
Type
Option
Sub Cmd
Access Password)
CRC