Fault_msg_power_too_low - 106h, Cause, Solution – ThingMagic M5e-Compact User Manual
Page 214: Fault_unimplemented_feature - 109h, Fault_invalid_baud_rate - 10ah
![background image](/manuals/640737/214/background.png)
Common Error Messages
214
Appendix C: Error Messages
FAULT_MSG_POWER_TOO_LOW - 106h
Cause
A message was received to set the read or write power to a level that is lower than the
current HW supports.
Solution
Check the HW specifications for the supported powers and insure that level is not
exceeded. The M5e supports powers between 5 and 30 dBm. The M5e-Compact units
support power from 10 dBm to 23 dBm.
FAULT_UNIMPLEMENTED_FEATURE - 109h
Cause
Attempting to invoke a command not supported on this firmware or hardware.
Solution
Check the command being invoked against the documentation.
FAULT_INVALID_BAUD_RATE - 10Ah
Cause
When a Set Baud Rate (0x06h) command is issued for a rate that is not specified in the
Baud Rate table, this error message is returned.
Solution
Check the table of specific baud rates and select a baud rate. Send the baud rate in the
hex format. See
.