1 system configurations and options – Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual
Page 6

2
iQUBE
2
Installation Manual
Diagnostics
Advanced diagnostic capabilities of the iQUBE
2
include power supply and excitation voltage monitoring; load cell
connection faults; and load cell overload, under-load, balanced load, load cell drift, peak-to-peak noise, and zero
reference errors. Diagnostic information can be included in the weight data itself or monitored on a communica-
tions channel separate from the weight data.
See Section 6.0 on page 47 for more information about iQUBE
2
diagnostics.
Transient Protection
For environments where extreme transients can be present (for example, truck scales), additional transient protec-
tion is available. These optional, replaceable boards are designed to protect the power supply lines by minimizing
the effects of nearby lightning strikes. Transient protection boards are recommended on each end of a power supply
run when an external DC supply is used, and on any power supply cables to secondary units where the secondary
enclosure runs are longer than 75 feet. The iQUBE
2
transient protection board option, PN 110949, includes a
mounting bracket.
1.1
System Configurations and Options
Table 1-1 lists the standard iQUBE
2
models, including the number of channels, enclosure material (fiber-reinforced
plastic [FRP], or stainless steel [SST]), enclosure size (in inches), and whether the model includes the internal 7.5
VDC power supply (PN 76556).
Small (8 x 10) enclosures can accommodate up to two iQUBE
2
boards (8 channels); large (10 x 12) enclosures can
accommodate up to three boards (12 channels). The maximum system configuration (16 channels) requires at least
two enclosures.
Communications Option Cards
The option cards listed in Table 1-2 are available to extend the communications capabilities of the iQUBE
2
. The
option cards are installed in connector J9 on the iQUBE
2
CPU board (see Figure 2-2 on page 8).
Power Supply Options
The iQUBE
2
can be powered by either the internal 7.5 VDC power supply (PN 76556) or by an external 12 VDC
power supply (PN 108434). The external DC power supply is mounted in its own 8 x 6 x 4-inch enclosure, and
includes a transient protection board for circuit protection.
See Section 8.3 on page 58 for information about calculating power requirements for particular system
configurations.
Model PN
Channels
Enclosure Material
Enclosure Size
Includes Power Supply
108425
4
FRP
8 x 10
yes
108429
4
FRP
8 x 10
no
108426
4
FRP
10 x 12
yes
108430
4
FRP
10 x 12
no
108427
8
FRP
10 x 12
yes
108431
8
FRP
10 x 12
no
108428
4
SST
8 x 10
yes
108432
4
SST
8 x 10
no
Table 1-1.
iQUBE
2
Models
Model / Option
PN
Fiber-optic interface card
77143
Ethernet interface card
77142
Wireless Ethernet card
108671
USB interface card
93245
Serial interface card
108579
Table 1-2.
iQUBE
2
Communications Option Cards