Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual
Page 46

42
iQUBE
2
Installation Manual
RESETCONFIGURATION
Reset system, restore to factory defaults
—
RESETDEFAULTS
Reset system defaults but retain M/S
communications configuration (IDs and
addresses)
—
SYSMODE
Show current SW1 setup switch position
Returns SETUP if SW1 is in CFG position;
WEIGH if SW1 is in OFF position
VOLTSEXC
Show primary board excitation voltage
—
VOLTSPS
Show primary board power supply voltage
—
WHOAMI
Returns information about the
iQUBE
2
including
master ID, version, and port configuration.
—
* These commands also store the configuration to EEPROM.
Command
s = scale number
Description
Values
SX
Start streaming for all scales
—
EX
End streaming for all scales
—
SCs.SX
Start streaming for scale s
—
SCs.EX
End streaming scale s
—
P
Write one frame of polling format from all scales
—
S
Write one frame of streamed format from all scales
—
SCs.COUNTS
Read A/D counts
—
SCs.CMV
Read corrected mV value
—
SCs.SIM
Emulate cell
NONE, 1–16
SCs.WEIGHT
Read weight value
—
SCs.ZERO
Perform zero operation for scale s
—
SCs.P
Write one frame of polling format from scale s
—
SCs.S
Write one frame of streamed format from scale s
—
SCs.TARE
Perform pushbutton tare operation for scale s
—
SCs.SETTARE
Perform keyed tare operation for scale s
—
SCs.PRINT
Perform print operation for scale s
—
SCs.CLRTARE
Perform clear tare operation scale s
—
SCs.GROSSNET
Toggle gross/net mode for scale s
—
SCs.GROSS
Set scale s to gross mode
—
SCs.NET
Set scale s to net mode
—
SCs.PRI
Set scale s to primary units
—
SCs.SEC
Set scale s to secondary units
—
SCs.UNITS
Toggle primary/secondary units for scale s
—
SCs.ZERO
Perform zero operation for scale s
—
Table 5-3.
iQUBE
2
Weigh Mode Commands
Command
Description
Values
Table 5-2.
iQUBE
2
System Commands (Continued)