Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual
Page 47

Serial Commands
43
See Section 7.0 on page 52 for more information about data formatting commands.
Command
s = scale number
Description
Values
SCs.STREAM
Enable streaming for
iQUBE
2
port
OFF, COM1, COM2, COM1&2
SCs.GFMT
Set gross format for scale s
FMT1–FMT6
SCs.NFMT
Set net format for scale s
FMT1–FMT6
SCs.SFMT
Set stream format for scale s
FMT1–FMT6
SCs.PFMT
Set polling format for scale s
FMT1–FMT6
FMTn
Set format n
specify up to 128 characters
Table 5-4.
iQUBE
2
Data Formatting Commands
Command
s = scale number
Description
Values
SCs.GRADS
Graduations
1–100 000
SCs.CAPACITY
Returns calculated scale capacity
SCs.ZTRKBND
Zero track band
SCs.ZRANGE
Zero range
SCs.MOTBAND
Motion band
SCs.OVRLOAD
Overload
FS+2%, FS+1D, FS+9D, FS
SCs.DFSENS
Digital filter cutout sensitivity
LIGHT, MEDIUM, HEAVY
SCs.DFTHRH
Digital filter threshold count
NONE, 10, 20, 30, 50, 100, 150, 200, 250,
500, 1000, 2500, 5000, 7500, 10000, 12500,
15000
SCs.UID
Set UID of primary unit
nnnnnnn
SCs.CONSNUM
Consecutive numbering
1–9999999
SCs.CONSTUP
Consecutive number start-up value
nnnnnnn
SCs.PRI.DECPNT
Primary units decimal position
8.88888, 88.8888, 888.888, 8888.88,
88888.8, 888888, 888880, 888800
SCs.PRI.DSPDIV
Primary units display divisions
1D, 2D, 5D
SCs.PRI.UNITS
Primary units
LB, KG, OZ, TN, T, G, NONE
SCs.SEC.DECPNT
Secondary units decimal position
8.88888, 88.8888, 888.888, 8888.88,
88888.8, 888888, 888880, 888800
SCs.SEC.DSPDIV
Secondary units display divisions
1D, 2D, 5D
SCs.SEC.UNITS
Secondary units
LB, KG, OZ, TN, T, G, NONE
SCs.SEC.MULT
Secondary units multiplier
0.00001–9999.99
SCs.TAREFN
Tare function
BOTH, NOTARE, PBTARE, KEYED
SCs.REGULAT
Regulatory compliance
NTEP, OIML, CANADA, NONE
SCs.NAME
Scale name
Scale1,scale_name (24 characters, maximum)
SCs.NCELLS
Assign load cells
Order entry determines cell
pairing relationships.
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 (specify
comma-separated list of load cell numbers
associated with this platform) or NONE (to
clear load cell list)
SC5.SCALES
Sets up the total scale (Scale 5)
SCs.CALMULT
Calibration multiplier
1.0, number
Table 5-5.
iQUBE
2
Scale Configuration Commands
Note