2 weight data status codes, 3 diagnostic codes, Weight data status codes – Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual
Page 58: Diagnostic codes

54
iQUBE
2
Installation Manual
7.1.2
Weight Data Status Codes
Table 7-3 lists the weight data status codes used in iQUBE
2
data streams. See Section 7.1.3 for information about
diagnostic status codes.
7.1.3
Diagnostic Codes
When using the diagnostic data stream, only one diagnostic status code is returned for the scale in a single data
frame. The diagnostic codes shown in Table 7-4 are listed in order of importance, from most critical to least critical
error type; only the most critical diagnostic code is returned in the data stream.
All current diagnostic errors can be queried using the diagnostic serial commands (see Section 6.0 on
page 46).
Field
Status Code
Meaning
Positive
<–>
Negative
<^>
Overrange
<]>
Underrange
L
Pounds
K
Kilograms
T
Tons
M
Metric tons
G
Grams
O
Ounces
R
Grains
None
G
Gross
N
Net
g
Emulated gross
n
Emulated net
Valid
I
Invalid (see Note below)
M
In Motion
O
Over/underrange
Z
Center of zero
Table 7-3. Weight Data Codes
Field
Status Code
Meaning
P
Power supply
S
Secondary communication
E
Excitation
C
Cell connection
R
Zero reference
V
Overloaded cell
D
Drift
U
Underloaded cell
N
Peak noise
L
Unbalanced cell
No error
Table 7-4. Diagnostic Status Codes
Note