Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual
Page 54

48
320IS Plus Installation Manual
Command
Description
Values
REGULAT
Regulatory compliance
NTEP, OIML, CANADA, NONE
REGWORD
Regulatory word
GROSS, BRUTTO
CONSNUM
Consecutive number
0–999 999
CONSTUP
Consecutive number start-up value
0–999 999
PWRUPMD
Power up mode
GO, DELAY
SAMPSIZ
Sample size
5, 10, 20, 50, 100, PCWGT
CNTMOD
Count mode access
DISABLE, ENABLE
UID
Unit identifier
000000–999999
STNDBY
Standby
0-255
DATEFMT
Date format
MMDDYY, DDMMYY, YYMMDD, YYDDMM
DATESEP
Date Separator
SLASH, DASH, SEMI
TIMEFMT
Time format
12HOUR, 24HOUR
TIMESEP
Time separator
COLON, COMMA
Table 5-7. PROGRM EDP Commands
Command
Description
Values
GFMT
Gross demand print format string
See Section 6.0 on page 53 for detailed information
NFMT
Net demand print format string
SPFMT
Setpoint demand print format
string
CFMT
Count demand print format
Table 5-8. PFORMT EDP Commands
Command
Description
Values
SETPOINT
Setpoint number
1-8
KIND
Setpoint Kind
GROSSSP, NETSP,ACCUM, +RELSP, -RELSP,
%RELSP, RESREL, PAUSE, DELAY, WAITSS,
COUNTER, AUTOJOG, COZ, INMOTON,
INRANGE, -GROSS, -NET, BATCHPR, TIMER,
CONCUR
VALUE
Setpoint value
number
PSHTAR
Push tare
OFF, ON
PSHPRN
Push print
OFF, ON, WAITSS
PSHACCM
Push accumulate
OFF, ON, NQUIET
TRIP
Trip
HIGHER, LOWER, INBAND, OUTBND
BANVAL
Band value
number
HYSTER
Hysteresis
number
ALARM
Alarm
OFF,ON
PREACT
Preact
OFF, ON, LEARN, FLOW
PREVAL
Preact value
number
BATCH
Batch step enable
OFF, ON
ACCESS
Setpoint access
ON, OFF, HIDE
Table 5-9. SETPNT EDP Commands