8 display part weight, 9 display or change time/date, 10 print ticket – Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual
Page 14: 11 display or change setpoint value, 12 turn setpoint on or off, 13 display or clear accumulator, Display part weight, Display or change time/date, Print ticket, Display or change setpoint value

8
320IS Plus Installation Manual
1.7.8
Display Part Weight
To view gross and net weight parts, press
MODE
to switch from count display mode to normal weighing mode.
To view the current piece weight while in count mode, press
DISPLAY TARE
key.
1.7.9
Display or Change Time/Date
Requires optional I/O Module (PN 72721).
To display the date, press the
asterisk (*)
key once; press
asterisk (*)
a second time to display the time.
To set the date, press the
asterisk (*)
key once. Use the numeric keypad to enter the date, then press the
ENTER
key.
Use the numeric keypad to enter the date in the same format configured for the indicator: MMDDYY, DDMMYY,
or YYMMDD.
To set the time, press the
asterisk (*)
key twice. Use the numeric keypad to enter the time in 24-hour format, then
press the
ENTER
key.
1.7.10
Print Ticket
Requires optional I/O Module (PN 72721).
Wait for the standstill annunciator (
). Press the
key to send data to the serial port. Standstill must be
lit to print.
1.7.11
Display or Change Setpoint Value
To display a setpoint value, press the
SETPOINT
key. To change the setpoint value, display the current value, then
use the numeric keypad to enter the new value and press the
ENTER
key.
1.7.12
Turn Setpoint On or Off
Requires optional I/O Module (PN 72721).
To turn a setpoint off at the front panel. With the correct setpoint displayed, press
CLEAR
to turn the setpoint off.
To re-enable a setpoint that has been turned off at the front panel, press the
SETPOINT
key, then press
ENTER
to
turn the setpoint back on.
1.7.13
Display or Clear Accumulator
If the accumulator function is enabled, the current net weight is added to the accumulator each time the indicator
performs a print operation.
•
To display the current accumulator value, press the
ACCUM
key.
•
To clear the accumulator, press
ACCUM
to show the current value, then press the
CLEAR
key twice to
reset the accumulator.