Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual
Page 41

320IS Plus Installation Manual - Configuration
35
Level 3 submenus
GROSSP
NETSP
+RELSP
–RELSP
%RELSP
VALUE
TRIP
BANVAL
HYSTER
PREACT
PREVAL
RELNUM
BATCH
PSHACC
PSHTAR
PSHPRN
ALARM
ACCESS
NAME
DIGOUT
Configure GROSSP, NETSP, and RELSP setpoints. See Figure 3-8 on page 33 and 
Level 4 parameter descriptions.
PAUSE
DELAY
WAITSS
PSHTAR
PSHPRN
PSHACC
ACCESS
NAME
DIGOUT
VALUE
Configure PAUSE, DELAY, and WAITSS setpoints. See Figure 3-9 on page 33 and 
Level 4 parameter descriptions.
COUNTR
AUTJOG
COZ
NMOTON 
NRANGE
–GROSS
–NET
BATPRO
VALUE
ACCESS
NAME
DIGOUT
Configure COUNTR, AUTJOG, COZ, NMOTON, NRANGE, –GROSS, –NET, AND 
BATCHPR setpoints. See Figure 3-10 on page 33 and Level 4 parameter 
descriptions.
TIMER
CONCUR
VALUE
START
END
ACCESS
NAME
DIGOUT
Configure TIMER and CONCUR setpoints. See Figure 3-11 on page 34 and Level 4 
parameter descriptions.
Level 4 submenus
VALUE
number
GROSSP, NETSP, RELSP setpoint types: Specifies the target weight value.
DELAY, AUTJOG, TIMER, and CONCUR setpoint types: Specifies, in 0.1-second 
intervals, a time value in the range 0–65535.
COUNTR setpoint types: Specifies the number of consecutive batches to be run.
TRIP
HIGHER
LOWER
INBAND
OUTBND
GROSSP, NETSP, and RELSP setpoint types: Specifies whether the setpoint is 
tripped when the weight is higher or lower than the setpoint value, within a band 
established around the value, or outside of that band. 
In a batch sequence with TRIP=HIGHER, the associated digital output is active until 
the setpoint value is reached or exceeded; with TRIP=LOWER, the output is active 
until the weight goes below the setpoint value.
BANVAL
number
GROSSP, NETSP, and RELSP setpoint types with TRIP=INBAND or OUTBND: 
Specifies a weight equal to half the band width. The band established around the 
setpoint value is VALUE ±BANVAL. 
SETPTS Menu
Parameter
Choices
Description