5 program menu, Program menu, Table 3-6. program menu parameters – Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual
Page 36

30
320IS Plus Installation Manual
3.2.5
Program Menu
Figure 3-5. Program Menu
PROGRM Menu
Parameter
Choices
Description
Level 2 submenus
PWRUPM
GO
DELAY
Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.
In DELAY mode, the indicator performs a power up display test, then enters a 30–second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset and
the warm up period is repeated.
COUNT
ACCESS
SPLSIZ
Specifies whether operator has access to piece count mode and the default sample size used
for parts counting. See Level three submenu for parameter descriptions.
REGULA
NTEP
OIML
CANADA
NONE
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.
NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.
REGWORD
GROSS
BRUTTO
Regulatory word — Sets the term displayed when weighing in gross mode. Selecting BRUTTO
replaces the Gross annunciator with Brutto.
CONSNU
000000
number
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation.
The initial value of this parameter is set to the start up value specified on the CONSTU
parameter. Changing either CONSTU or CONSNU immediately resets the consecutive number
used for printing.
Table 3-6. Program Menu Parameters
XXXXXXX
XXXXXXX
PWRUPM
GO
OIML
REGULA
DELAY
SETPNT
PROGRM PFORMT
SERIAL
CALIBR
CONFIG FORMAT
NTEP
CANADA
COUNT
VERS
DIGIN ALGOUT
ACCESS
SPLSIZ
10
20
50
100
PCWGT
DSABLE
ENABLE
NONE
000000
number
CONSNU
000000
number
CONSTU
DATFMT
MMDDYY
DATE
DDMMYY
YYMMDD
YYDDMM
TIMFMT
12HOUR
TIME
24HOUR
TIMSEP
COLON
COMMA
number
000000
SPPWD
number
000000
STNDBY
0-255
000
ACCUM
ON
OFF
DATSEP
SLASH
DASH
SEMI
UID
5
GROSS
BRUTTO
REGWORD