Chapter 3. installation and configuration, Choosing a location, Chapter 3. installation and configuration -1 – Dell PowerVault TL1000 User Manual
Page 39: Location criteria

Chapter 3. Installation and configuration
“Installing in a rack” on page 3-2
“Removing the accessor locking screw” on page 3-7
“Attaching the library to a server” on page 3-8
“Configuring your library with the
Web User Interface” on page 3-11
“Logging in to the Web User Interface” on page 3-12
“Checking firmware level” on page 3-13
“Configuring library settings” on page 3-14
“Configuring network settings” on page 3-16
“Configuring date and time settings” on page 3-17
“Configuring encryption settings” on page 3-18
“Configuring email notifications” on page 3-20
“Configuring trap notifications” on page 3-21
“Managing user access” on page 3-23
“Saving the library configuration” on page 3-24
“Configuring your library with the
Operator Panel” on page 3-24
“Logging in to the Operator Panel” on page 3-24
“Configuring network settings” on page 3-24
“Configuring library settings” on page 3-26
“Populating the library with cartridges” on page 3-27
“Verifying library and drive operation” on page 3-28
“Taking the Library Online” on page 3-29
“Registering for support notification” on page 3-29
To install and configure a TL1000 Tape Autoloader, complete these procedures in
the order they are presented.
Choosing a location
Table 3-1. Location criteria
Criteria
Definition
Room temperature
16 - 32 °C (60 - 90 °F)
Voltage
100 - 240 Vac. (4.0 to 1.5 A)
Note:
The power switch is on the rear of the
library and must be easily accessible.
Frequency
50 - 60 Hz
Relative humidity
20 - 80% non-condensing
Air quality
The library must be placed in an area with
minimal sources of particulate
contamination. Avoid areas near frequently
used doors and walkways, stacks of supplies
that collect dust, printers, and smoke-filled
rooms. Excessive dust and debris can
damage cartridges and the tape drive.
3-1
|
|