beautypg.com

Dell PowerVault TL1000 User Manual

Page 141

background image

Table A-1. Library error codes (continued)

Code (H)

Description

Panel Indication

Action Required

00DD

An error detected during bar code
reader firmware check. Suspect
the bar code reader cable
connection.

CHK 00DD

1.

Initiate an inventory. See “Conducting a
library inventory” on page 4-7
(Operator
Panel) or “Conducting a library inventory”
on page 4-22
(Web User Interface).

2.

Cycle the power supply and try again.

v

If the problem is corrected, run Library
Verify before normal library operations
resume.

v

If the problem persists, see “Contacting
Dell technical support” on page 7-2.

00E0

Write operation not finished
within 1 ms when writing data to
flash memory.

CHK 00E0

Cycle the power supply and try again.

v

If the problem is corrected, run Library Verify
before normal library operations resume.

v

If the problem persists, see “Contacting Dell
technical support” on page 7-2.

00E1

Clear operation not finished
within 10 seconds when clearing a
sector in flash memory.

CHK 00E1

00E2

Error detected in tape library
configuration stored in flash
memory.

CHK 00E2

00E3

Checksum error detected in flash
memory.

CHK 00E3

00F0

Sensor error #1.

Accessor encoder sensor B error
detected during blink check.
Suspect the accessor encoder
sensor B.

CHK 00F0

Appendix A. Error codes