Table A-1. Library error codes (continued)
Code (H)
Description
Panel Indication
Action Required
00B1
No media is contained in the
specified cell (Cell Empty).
Suspect the centering sensor, X
motor, or P motor.
CHK 00B1
Cycle the power supply and try again.
v
If the problem is corrected, run Library Verify
before normal library operations resume.
v
If the problem persists, see “Contacting Dell
technical support” on page 7-2.
00B2
Media detected in the accessor at
completion of centering check
operation. Suspect the centering
sensor.
CHK 00B2
1.
If the cartridge remains in the accessor, try to
move the cartridge from the accessor to the
I/O Station with the Operator Panel or Web
User Interface. Remove the cartridge from
the library and inspect for damage and
replace, if necessary.
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 7-2.
00B3
Media detected in the accessor at
completion of PUT operation.
Suspect the centering sensor.
CHK 00B3
00B8
accessor error #1.
Reverse REV position (PP1) error
(accessor origin not detected or
FWD position detected). Suspect
the P origin sensor, FWD sensor,
or P motor.
CHK 00B8
1.
Check the accessor locking screw and
remove it if it is installed. See “Removing the
accessor locking screw” on page 3-7.
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 7-2.
00B9
accessor error #2.
Forward FWD position (PP2)
error (accessor origin detected or
FWD not detected). Suspect the P
origin sensor, FWD sensor, or P
motor.
CHK 00B9
00BA
accessor error #3.
PUT/GET/bar code reader
position (PP4/PP5/PPBF/PPBR)
error (accessor origin or FWD
detected, or cell full). Suspect the
P origin sensor, FWD sensor, or P
motor.
CHK 00BA
00BC
During initialization, the accessor
origin could not be detected.
Suspect the P origin sensor, FWD
sensor, or P motor.
CHK 00BC
00BD
During accessor movement, the
movement stop condition
detected. Suspect the P encoder
sensor or P motor.
CHK 00BD
00BF
No gap condition detected at the
completion of accessor operation.
Suspect the centering sensor, P
origin sensor, FWD sensor, or P
motor.
CHK 00BF
Appendix A. Error codes