beautypg.com

Dell PowerVault TL1000 User Manual

Page 136

background image

Table A-1. Library error codes (continued)

Code (H)

Description

Panel Indication

Action Required

0053

Response acknowledge error
received from bar code reader.
Suspect the bar code reader cable
connection.

CHK 0053

1.

Initiate an inventory. See “Conducting a
library inventory” on page 4-7
(Operator
Panel) or “Conducting a library inventory”
on page 4-22
(Web User Interface).

2.

Cycle the power supply and try again.

v

If the problem is corrected, run Library
Verify before normal library operations
resume.

v

If the problem persists, see “Contacting
Dell technical support” on page 7-2.

0056

Receive data checksum error
received from bar code reader.
Suspect the bar code reader cable
connection.

CHK 0056

0057

Invalid data received from bar
code reader. Suspect the bar code
reader cable connection.

CHK 0057

0058

A bar code reader read-error
detected. Suspect the bar code
reader cable connection.

CHK 0058

0059

A bar code reader FLASH control
error detected. Suspect the bar
code reader cable connection.

CHK 0059

005A

A bar code reader diagnostics
error detected. Suspect the bar
code reader cable connection.

CHK 005A

005B

I

2

C I/F error. A transfer retry

detected. Suspect the bar code
reader cable connection.

CHK 005B

005C

I

2

C I/F error. Interrupt timeout

detected. Suspect the bar code
reader cable connection.

CHK 005C

005D

I

2

C I/F error.

Invalid signal (NAK) detected.
Suspect the bar code reader cable
connection.

CHK 005D

005E

I

2

C I/F error.

Bus arbitration lost error detected.
Suspect the bar code reader cable
connection.

CHK 005E

005F

I

2

C I/F error.

Ready condition does not occur.
Suspect the bar code reader cable
connection.

CHK 005F

0070

Calibration failed because the
accessor contains media. Suspect
the centering sensor.

CHK 0070

1.

Attempt to unload the cartridge from the
accessor. See“Moving cartridges” on page 4-6
(Operator Panel) or “Moving cartridges” on
page 4-20
(Web User Interface).

2.

Cycle the power supply and try again.

v

If the problem is corrected, run Library
Verify before normal library operations
resume.

v

If the problem persists, see “Contacting
Dell technical support” on page 7-2.

A-4

Dell PowerVault TL1000 Tape Autoloader User's Guide