Dell PowerVault TL1000 User Manual
Page 136

Table A-1. Library error codes (continued)
Code (H)
Description
Panel Indication
Action Required
0053
Response acknowledge error
received from bar code reader.
Suspect the bar code reader cable
connection.
CHK 0053
1.
Initiate an inventory. See “Conducting a
library inventory” on page 4-7 (Operator
Panel) or “Conducting a library inventory”
on page 4-22 (Web User Interface).
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 7-2.
0056
Receive data checksum error
received from bar code reader.
Suspect the bar code reader cable
connection.
CHK 0056
0057
Invalid data received from bar
code reader. Suspect the bar code
reader cable connection.
CHK 0057
0058
A bar code reader read-error
detected. Suspect the bar code
reader cable connection.
CHK 0058
0059
A bar code reader FLASH control
error detected. Suspect the bar
code reader cable connection.
CHK 0059
005A
A bar code reader diagnostics
error detected. Suspect the bar
code reader cable connection.
CHK 005A
005B
I
2
C I/F error. A transfer retry
detected. Suspect the bar code
reader cable connection.
CHK 005B
005C
I
2
C I/F error. Interrupt timeout
detected. Suspect the bar code
reader cable connection.
CHK 005C
005D
I
2
C I/F error.
Invalid signal (NAK) detected.
Suspect the bar code reader cable
connection.
CHK 005D
005E
I
2
C I/F error.
Bus arbitration lost error detected.
Suspect the bar code reader cable
connection.
CHK 005E
005F
I
2
C I/F error.
Ready condition does not occur.
Suspect the bar code reader cable
connection.
CHK 005F
0070
Calibration failed because the
accessor contains media. Suspect
the centering sensor.
CHK 0070
1.
Attempt to unload the cartridge from the
accessor. See“Moving cartridges” on page 4-6
(Operator Panel) or “Moving cartridges” on
page 4-20 (Web User Interface).
2.
Cycle the power supply and try again.
v
If the problem is corrected, run Library
Verify before normal library operations
resume.
v
If the problem persists, see “Contacting
Dell technical support” on page 7-2.
A-4
Dell PowerVault TL1000 Tape Autoloader User's Guide