Drive error codes, Web user interface error messages, A-11 – Dell PowerVault TL1000 User Manual
Page 143: Web user error messages

Drive error codes
Table A-2. Drive error codes
Code (H)
Description
Panel indication
Action Required
0200
Invalid data sent to drive.
NAK detected.
CHK 0200
1.
Reseat all cables. See “Reseating
cables” on page 6-10.
2.
Cycle the power supply and try
again.
v
If the problem is corrected, run
Library Verify before normal
library operations resumes.
v
If the problem persists, see
“Contacting Dell technical
support” on page 7-2.
0201
Timeout error occurred
while drive is waiting for
response.
CHK 0201
0203
Drive disconnected.
CHK 0203
0205
Drive busy.
CHK 0205
0206
Command could not be
executed because drive is
not mounted.
CHK 0206
020E
Drive error detected.
CHK 020E
020F
Unsupported drive
detected.
CHK 020F
0222
Media could not be
ejected because drive is
in Prevent Medium
Removal state.
CHK 0222
1.
Release the drive Prevent Medium
Removal state from the host.
2.
Reseat all cables. See “Reseating
cables” on page 6-10.
3.
Cycle the power supply and try
again.
v
If the problem is corrected, run
Library Verify before normal
library operations resumes.
v
If the problem persists, see
“Contacting Dell technical
support” on page 7-2.
Web User Interface error messages
Table A-3. Web user error messages
Title
Message
Issuing Panel
Error
Users full.
User Access
You cannot remove yourself.
User Access
Appendix A. Error codes
A-11