3.2. Remote control commands
751 GPD Titrino
124
*Parameter Tree part "Parameters for DOS"
Ã
.
DosPara
Dosing parameters
³ Ã
.Type
Type of dosing
volume, time, rate
3.2.2.52.
³ Ã
.Volume
Volume dosing
³ ³ Ã
.Volume
Volume
0...10...99 999.99
ditto
³ ³ Ã
.DisType
Second dosing criterion
time, rate
ditto
³ ³ Ã
.Rate
Rate
0.001...150, max.
ditto
³ ³ Ã
.Time
Dosing time
1...100...999 999
ditto
³ Ã
.Time
Time dosing
³ ³ Ã
.Time
Dosing time
1...100...999 999
ditto
³ ³ Ã
.DisType
Second dosing criterion
volume, rate
ditto
³ ³ Ã
.Rate
Rate
0.001...150, max.
ditto
³ ³ Ã
.Volume
Volume
0...10...99 999.99
ditto
³ Ã
.Rate
Rate dosing
³ ³ Ã
.Rate
Rate
0.001...150, max.
ditto
³ ³ Ã
.StopType
Second dosing criterion
volume, time
ditto
³ ³ Ã
.Time
Dosing time
1...100...999 999
ditto
³ ³ Ã
.Volume
Volume
0...10...99 999.99
ditto
³ Ã
.Pause
Waiting time after start volume
0...999 999
3.2.2.53.
³ Ã
.TDelta
Time interv.for meas.acquisition
1...10...999 999
3.2.2.54.
³ Ã
.DosUnit
Selection of the dosing unit
internal D0, external D1,
³ ³
external D2
3.2.2.17.
³ Ã
.Temp
Titration temperature
-170.0...25.0...500.0
3.2.2.55.
³ ³
Ã
.
StopCond
Stop conditions
³ Ã
.VStopStop volume
³ ³ Ã
.Type
Type of stop volume
abs., rel., OFF
3.2.2.20.
³ ³ Ã
.V
Volume for absolute stop volume
0...99.99...9999.99
ditto
³ ³ Ã
.Factor
Factor for relative stop volume
0...
±
999 999
ditto
³ Ã
.FillRate
Filling rate
0.01...150.0, max.
3.2.2.23.
³ ³
Ã
.
StatisticsStatistics
³ Ã
.Status
Status of statistics calculation
ON, OFF
3.2.2.24.
³ Ã
.MeanN
No.of individual determinations
2...20
ditto
³ Ã
.ResTab
Result table
³ ³ Ã
.Select
original,delete n,delete all
ditto
³ ³ Ã
.DelN
Deletion of individual results
1...20
ditto
³ ³
Ã
.
Monitoring
Monitoring
³ Ã
.MeasVal
Monitoring of measured values
³ ³ Ã
.MeasMode
Measured value
pH, U, Ipol, Upol, OFF
3.2.2.56.
³ ³ Ã
.MeasInput
Measuring input
1, 2, diff.
ditto
³ ³ Ã
.PCurrent
Polarization current
0...1...
±
127
ditto
³ ³ Ã
.PVoltage
Polarization voltage
0...400...
±
1270
ditto
³ ³ Ã
.PolElectrTest
Test for polarized electrodes
ON, OFF
ditto
³ ³ Ã
.pH
Limits for monitoring of pH values
³ ³ ³ Ã
.LowLim
Lower limit
-20.00...20.00
ditto
³ ³ ³ Ã
.UpLim
Upper limit
-20.00...20.00
ditto
³ ³ Ã
.U
Limits for monitoring of U values
³ ³ ³ Ã
.LowLim
Lower limit
-2000...2000
ditto
³ ³ ³ Ã
.UpLim
Upper limit
-2000...2000
ditto
³ ³ Ã
.Ipol
Limits for monitoring of Ipol values
³ ³ ³
:
as for U
³ ³ Ã
.U
Limits for monitoring of Upol values
³ ³ ³
:
as above
³ ³ Ã
.Action
Action if out of limits
end, hold, wait, none
ditto