Measurements
65
Out-of-Band and In-Band, Out-of-Channel Spurious
Note:
These two measurement methods are not listed on
the interface.
Out-of-Band & In-Band, Out-of-Channel Spurious measures the
distortion and interference inside or outside a system band.
1. Click on Mark & Limit.
2. Click on the Marker 1 2 3 4 5 6 selection to select marker 1.
Note:
The bracketed number indicates the active marker.
3. Click on On/Off.
4. Use the arrow keys, the number keys or mouse scroll wheel to
move the marker over one of the spurs.
5. Compare the value of the marker to the specified allowable level of
Out-of-Band (In-Band, Out-of-Channel) spurious emissions for the
corresponding channel transmit frequency.