Measurements

65

Out-of-Band and In-Band, Out-of-Channel Spurious

Note:

These two measurement methods are not listed on

the interface.

Out-of-Band & In-Band, Out-of-Channel Spurious measures the
distortion and interference inside or outside a system band.

1. Click on Mark & Limit.

2. Click on the Marker 1 2 3 4 5 6 selection to select marker 1.

Note:

The bracketed number indicates the active marker.

3. Click on On/Off.

4. Use the arrow keys, the number keys or mouse scroll wheel to

move the marker over one of the spurs.

5. Compare the value of the marker to the specified allowable level of

Out-of-Band (In-Band, Out-of-Channel) spurious emissions for the
corresponding channel transmit frequency.