beautypg.com

Rockwell Automation MinPak Plus DC Drives Kits User Manual

Page 7

background image

6

Table 2.C - SPECIFICATIONS

AĆC Line Input Voltage

115/230 VAC (nominal)

singleĆphase only

Line Voltage Variation

"10% of nominal

AĆC Line Frequency

Single Phase, 50/60 Hz

(Jumper selectable)➀

Line Frequency Range

48Ć62 Hz

Output Voltages

(armature andfield)

See Table 2.D

ControllerĆDrive HP Range

1/4Ć3/4 hp (with 115 VAC input)

1/2Ć5 hp (with 230 VAC input)

Direction Control

Forward/Reverse

Maximum SpeedAdjustment

50Ć100% of base motor speed

(user adjustable)

Minimum SpeedAdjustment

0Ć50% of base motor speed

(user adjustable)

Operator SpeedAdjustment

Infinitely adjustable with

optional control pot

(0Ć100% of base speed)

Operator Torque Adjustment

Infinitely adjustable at

optional control pot

(10Ć150% of rated load)

Controllable SpeedRange

20:1

Current Limit

Factory shipped: 150% of full load

User adjustable: 10Ć150% of full load

(User separately adjustable

positive and negative)

Regulation

(with 95% loadchange)

3Ć5% with voltage feedback

1.0% with specified tachometer feedback

0.5% with specified tachometer feedback

Minimum Loadfor Stable Operation

5%

Armature Circuit OverloadCapacity

150% of armature current rating

for 1 minute (max.)

Efficiency

(rated speed/rated load)

Controller only: 97%

Complete drive including

motor: 85% (typical)➁

Displacement Power Factor

68% (typical)➁

Circuit Breaker Interrupting Capacity

1000 amps to 1 hp

5000 amps 1Ć1/2Ć5 hp

Transient Protection

MOV, Output RC Circuit, and

Thyristor RC Circuits (4)

Controller Service Factor

1.0

Duty

Continuous

Storage Ambient Temperature

0

°

Ć55

°

C (32

°

-131

°

F)

Operational Ambient Temperature

Chassis: 0

°

-55

°

C (32

°

-131

°

F)

Cabinet: 0

°

-40

°

C (32

°

-104

°

F)

Relative Humidity

(storage andoperational)

5-95%

(without condensation)

Operational Altitude

To 3300 ft (1000 m) above

sea level without derating

Controller Enclosure Rating

NEMA Type 4 and 12➂

(watertight, as defined)

Controller Weight (approx.)

3/4, 1Ć1/2, 3 hp = 14.4 lb (6.5 kg)

5 hp = 15.1 lb (6.9 kg)

Shipping Box Weight (approx.)

3/4, 1Ć1/2, 3 hp = 16.4 lb (7.4 kg)

5 hp=17.1 Ib (7.8kg)

(Figures include all optional Kits)

Controller Dimensions (LWD)

14Ć15/16 x 9Ć7/8 x 7Ć3/8 inch

(370 x 247 x 184 mm)

5%

Acceleration/Deceleration Rates

0.5Ć30 sec. linear time

(userĆadjusted separately)

See Paragraph 3.9.

Typical percent shown. Exact figure dependent on motor

base speed and frame size.