82 Specifications
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
-20 to +65°C (-4 to +149°F)
-40 to +85°C (-40 to +185°F)
95% non-condensing
Physical
Dimensions
Terminal Screw Torque
Height: 3.8in (97mm)
Width: 3.7in (94mm)
Depth: 3.7in (94mm)
7 pound-inches (0.6Nm)
Approvals
(when product or packaging is marked)
*See the Product Certification link at
www.rockwellautomation.com for Declarations
of Conformity, Certificates and other
certification details.
XM-160/161/162 Direct Vibration Technical Specifications
Product Feature
Specification
UL
UL Listed for Ordinary
Locations
UL
UL Listed for Class I, Division 2
Group A, B, C, and D Hazardous
Locations
CSA
CSA Certified Process Control
Equipment
CSA
CSA Certified Process Control
Equipment for Class I, Division
2 Group A, B, C, and D
Hazardous Locations
EEX*
European Union 94/9/EEC ATEX
Directive, compliant with EN
50021; Potentially Explosive
Atmospheres, Protection “n”
CE*
European Union 89/336/EEC
EMC Directive
C-Tick*
Australian
Radiocommunications Act,
compliant with:
AS/NZS 2064, Industrial
Emissions