Configure doy – Rockwell Automation 2080-LC10-12DWD Micro810 Programmable Controllers User Manual User Manual
Page 83
Rockwell Automation Publication 2080-UM001D-EN-E - September 2012
75
Quickstarts Appendix C
6. Press the DOWN arrow button once and select SR FUNCTION. Press
the OK button. The TON function block to control Output 0 becomes
available.
7. Press the push button connected to I01. ET starts to elapse.
8. When the current ET equals PT, output O00 is energized, and the pilot
light turns on.
Configure DOY
1. Power up the Micro810 controller.
The Micro810 splash screen briefly appears after power up.
2. The status display shows PROG mode, the day and time, and the I/O
status. Press the ESC and OK buttons at the same time to navigate to the
Main Menu.
3. Press the DOWN arrow button once to select SR function. Press the OK
button.
4. Press the DOWN arrow button once to navigate to the function block
controlling Output 3 (DOY).
DOY – Sample Parameter Configuration
Parameter Field
Configuration Value
Q
Q03
Channel
A
EN
I03
Y/C
0
On
11/08/18 (YY/MM/DD)
Off
11/08/19 (YY/MM/DD)