Formatting and Interpreting Data Blocks

Chapter 7

7Ć38

a position-with-offset move in a moveset
an offset command from the command block

This parameter has a 4-digit BCD value that can be in the range +0.0001
to +0.7999 inches or +0.001 to +7.999 mm (Figure 7.27).

Figure 7.27

Offset Word

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Offset

Word 24 (Axis 1)

Word 43 (Axis 2)

Word 62 (Axis 3)

inch metric

Sign:

0 = +

1 = -

11049

Offset value, inches or

millimeters, BCD format

decimal

point

decimal

point

Tachometer Conversion Factor

The servo positioning assembly uses bits 00 thru 03 of word 25 (44, 63)
for its loss-of-feedback detection feature (Figure 7.28). The tachometer