beautypg.com

Copy acd file – Rockwell Automation 1756-HSC ControlLogix High Speed Counter Module User Manual

Page 98

background image

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011

98 1756-HSC Module History

14. Click OK.

The ladder logic in your RSLogix 5000 project will copy the module
configuration from this profile to the generic profile.

15. Click OK.

16. Save the project.

Copy ACD file

1. Open the copied .ACD file in a new instance of RSLogix 5000 software.

2. In the Controller Organizer of the sample project, extend the

User-Defined Data Types to view the 1756-HSC data types.

3. Copy and paste each of the User-Defined Data Types (UDTs), one at a

time, into your RSLogix 5000 project.

4. Do one of the following to create tags and specify the appropriate

1756-HSC module UDTs for each (HSC_CONFIG,
HSC_IN_STRUCT, and HSC_OUT_STRUCT).

Define Your Own Tags

a. To define your own tags, double-click Controller Tags on the

Controller Organizer.

b. Click the Edit Tags tab at the bottom of the Controller Tags window.
c. In the blank entry field at the bottom of the window, enter your tag

name and data type.

Use Default Tags from RSLogix 5000 Software

a. To use default tags from RSLogix 5000 (which were imported from

the sample download at the start of these procedures), double-click
Controller Tags on the Controller Organizer.