beautypg.com

Class code 0x05 — connection – Rockwell Automation 1336-GM6 Enhanced DeviceNet Communications Module User Manual

Page 114

background image

C-6

DeviceNet Objects

Class Code 0x05 — Connection

The Connection Class allocates and manages the internal resources
associated with both I/O and Explicit Messaging Connections. The
specific instance generated by the Connection Class is referred to as a
Connection Instance or a Connection Object.

Important: An externally visible interface to the Connection Class
across Explicit Messaging Connections DOES exist. Unless
otherwise noted, all services/attributes noted in the following sections
are accessible using Explicit Messaging.

A Connection Object within a particular module actually represents
one of the end-points of a Connection. It is possible for one of the
Connection end-points to be configured and “active” (e.g.,
transmitting) without the other end-point(s) being present.
Connection Objects are used to model the communication specific
characteristics of a particular Application-to-Applications(s)
relationship. A specific Connection Object Instance manages the
communication-specific aspects related to an end-point.

A Connection Object on DeviceNet uses the services provided by a
Link Producer and/or Link Consumer to perform low-level data
transmission and reception functions.

Class Attributes

Instances

Attribute ID

Access Rule

Name

Data Type

Description

1

Get

Revision

UINT

Revision of the Connection Object class definition
upon which the implementation is based
Range 1 – 65535

Instance

Description

1

Group 2 Messaging

2

Group 2 Polling

4

Group 2 COS/Cyclic

6

Group 3 Messaging

7

Group 3 Messaging

8

Group 3 Messaging

9

Group 3 Messaging

10

Group 3 Messaging

This manual is related to the following products: