Dh+ parameters – Rockwell Automation 1395 Multi-Comm Hardware/Software User Manual

Page 131

background image

Table of Contents

8–36

Table 8-D. DH+ Parameter Summary (cont.)

DEC

588

589

590

591

592

593

594

595

HEX

NAME

UNITS

INIT

MIN

MAX

EE

FUNCTION

PORT

24CH

24DH

24EH

24FH

250H

251H

252H

253H

A>Redund Chan No

A>ChA DH Rd Nde 2

A>ChA DH Rd Wrd 2

A>ChA DH Rd Nde 3

A>ChA DH Rd Wrd 3

A> ChB DH Rd Nde 4

A> ChB DH Rd Wrd 4

A>ChA DH Flt Sl

A

A

A

A

A

A

A

A

None

None

None

None

None

None

None

Bit Select

Setup

Setup

Setup

Setup

Setup

Setup

Setup

Setup

0

8

0

8

0

8

0

1

77

1

77

1

77

1

0

0

0

0

0

0

0

DH+ Parameters

The parameter definitions for the MCA board are dependent on the channel
configuration setup using DIP switches U5, U6, U14, and U15. When a
channel is setup for use on DH+ then the parameter definitions in this
section will apply. Refer to the DIP switch settings to determine channel
setup. Parameter definitions for channels setup for RIO are listed in the
previous section.

IMPORTANT: The DH+ Token Pass is not designed for control of the
drive or system. It should be used for transmittal of information such as
operator display readouts only. The RIO Control Link must be used for
control of the drive and system functions.

Parameter 400 – [A>ChA DH TP In 1]
Parameter 300 – [B>ChA DH TP In 1]

Use: Channel A DH+ Token Pass with data Input word #1
Parameter Type: Fast Source
Program Terminal Units: None
Minimum Value:
Maximum Value:
Default Value:
None

Description: This parameter is a fast source that contains data from the
global data passed with the network token. The specific node address and
word are defined by the DH Rd Nde1 and DH Rd Wrd1 parameters. The
value can be used by the MCA board directly or by other Drive functions
through a configuration link.