Chapter 8

Reference

8–10

Parameter 417 – [A>Mult2 FB Fract]
Parameter 317 – [B>Mult2 FB Fract]

Use: Fractional value Output from Multiply #2 function block
Parameter Type: Fast Source
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a fast source that contains the fractional
portion of the output resultant from the Multiply #2 function block. This
value can be used by the MCA board directly or by other Drive functions
through a configuration link. For example, it could be linked to the
Velocity reference fraction parameter to provide the Drive with a speed
reference input. If the block output overflows (exceeds the range of the
output) the “Function Block overflow parameter” (par. 567/517)
determines the board output value.

Parameter 418 – [A>Add FB Out]
Parameter 318 – [B>Add FB Out]

Use: Output from Add function block
Parameter Type: Fast Source
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None

Description: This parameter is a fast source that contains the output
resultant from the Add function block. This value can be used by the
MCA board directly or by other Drive functions through a configuration
link. If the block output overflows (exceeds the range of the output) the
“Function Block overflow parameter” (par. 567/517) determines the board
reaction.

Parameter 419 – [A>Filter FB Out]
Parameter 319 – [B>Filter FB Out]

Use: Output from Filter function block
Parameter Type: Fast Source
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None

Description: This parameter is a fast source that contains the output from
the Filter function block. This value can be used by the MCA board
directly or by other Drive functions through a configuration link.