beautypg.com

Thermal curves, Design guide & applications manual, Page 73 of 98 – Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 74

background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 73 of 98

Apps. Eng. 800 927.9474

800 735.6200

FREE AIR, H

FREE AIR, V

200 LFM

400 LFM

600 LFM

800 LFM

1000 LFM

21. Thermal Curves

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

Ambient Temperature (°C)

O

ut

pu

t P

ow

er

(W

at

ts

)

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

Ambient Temperature (°C)

O

ut

pu

t P

ow

er

(W

at

ts

)

Figure 21–23 — FinMod VI-J00 Family F1/ F3 configuration

5 V output

Figure 21–24 — FinMod VI-J00 Family F1 / F3 configuration

12 – 48 V output

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

Ambient Temperature (°C)

O

ut

pu

t P

ow

er

(W

at

ts

)

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

Ambient Temperature (°C)

O

ut

pu

t P

ow

er

(W

at

ts

)

Figure 21–25 — FinMod VI-J00 Family F2 / F4 configuration

5 V output

Figure 21–26 — FinMod VI-J00 Family F2 / F4 configuration

12 – 48 V output

FinMod VI-J00 Family

NOTE: Use as a design guide only. Verify final design by actual temperature measurement.

This manual is related to the following products: