beautypg.com

Ac input harmonic attenuator module (ham), Figure 13–10 — recommended ham filter, Figure 13–8 — enable output (e/o) – Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 41: Figure 13–9 — start-up / shut-down timing diagram, Table 13-1 — ham filter inductance range

background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 40 of 98

Apps. Eng. 800 927.9474

800 735.6200

13. AC Input Harmonic Attenuator Module (HAM)

L

IN

E

L

O

A

D

R

Cx

Cy

Cy

D1

D2

D3

HAM Filter P/N 30205

R = 235 K

Ω D1,2 = 1.5KE130CA D3 = 1.5KE150CA

MOV

*

P/N 30076

Cx = 1.5 uF(x2)SH Cy = 0.01 uF, Y2 type LC = 6.9 mH LD = 0.72 mH

*MOV required external to filter to meet normal mode transient surge requirements

CM

DM

Figure 13–10 — Recommended HAM filter

+OUT

P/OK

–OUT

E/O

A/S

18 kΩ, 1/4 W

"Power OK" Status

Low = OK

LOGIC

P/OK

–OUT

+OUT

E/O

S

G

D

A/S

Figure 13–6 — Auxiliary Supply (A/S)

Figure 13–7 — Power OK (P/OK)

LOGIC

E/O

–OUT

+OUT

P/OK

A/S

S

G

D

Figure 13–8 — Enable Output (E/O)

Outputs

DC-DC Converter(s)

Rectified Line

Enable Output (E/O)

DC Output

of HAM

Power OK (P/OK)

AC Mains

120 Vrms

Boost Voltage

195 Vdc

240 Vdc

Off at 195 Vdc

Off at 230 Vdc

230 Vdc

25 ms

10 ms

Off below 195 Vdc

Figure 13–9 — Start-up / shut-down timing diagram

A/S

E/O

P/OK

+OUT

–OUT

IAS ≤ 3 mA

19 – 23 V

+

DO NOT OVERLOAD
or directly connect a capacitor
to the A/S terminal.

A line filter is required to provide attenuation of
conducted emissions generated by the HAM module and
to protect it from line transients. It also presents a well
defined high frequency AC line impedance to the input of
the HAM. To meet the listed specifications, Vicor’s P/N
30205 line filter/transient suppressor or equivalent must
be used (Figure 13–10). The addition of a MOV external
to this filter is required to meet normal mode transient
surge requirements.

For applications using HAMD + BAMD or where the user
desires to construct a custom HAM filter, the filter should
be designed following Figure 13–10, the schematic of
Vicor’s P/N 30205 filter. The current carrying capability of
the inductors must be scaled proportionally to the number
of HAM modules used. Inductance values must be
selected according to Table 13–1. These limits are to
ensure proper operation of the HAM and do not
guarantee a system will meet conducted emissions
specifications.

For applications requiring magnetic field shielding, do not
place a ferrous EMI shield over the plastic cover of the
HAM module. This can cause thermal problems due to
induction heating effects.

LINE FILTER FOR HIGH BOOST HAM

Parameter

Min

Typ

Max

Unit

Differential Mode

0.2

0.35

0.75

mH

Inductance (LD)

Common Mode

3

6

mH

Inductance (LC)

Table 13-1 — HAM filter inductance range

This manual is related to the following products: