NOTE 1: To ensure proper heat transfer from the internal
modules to the heat sink, the mounting holes through the
heat sink (three holes on 2-up models) must contain
torqued screws at all times during operation, whether or
not the unit is mounted. If the unit is operated
unmounted, insert a #6 or M3.5 panhead screw through
each hole from below and secure with a nut on top,
torqued to 6 in-lbs (0.7 N-m).

NOTE 2: All PFC FlatPAC models are available with a
conduction cooled flat plate instead of the top heat sink.
Go to vicorpower.com for outline drawings. Refer to
Figure 19–4 for additional deratings for the -cc variants.

19. AC Input Power System (PFC FlatPAC)

0

100

200

300

400

500

600

20 25 30 35 40 45 50 55 60 65 70 75 80 85

Ambient Temperature (°C)

O

u

tp

u

t

P

o

w

e

r

(W

)

80

60

70

50

Cold Plate

Temp (°C)

300

350

400

450

500

550

600

85

110

135

160

185

210

235

260

Input Voltage (Vac)

O

u

tp

u

t

P

o

w

e

r

(W

a

tt

s

)

Figure 19–4 — Power de-rating conduction cooled option

Figure 19–5 — Output power start-up de-rating @ –30° C
(I-Grade only). 5 minute warm up required before full power (see
Figure 19–1) is available.