SAFETY CONSIDERATIONS
Shock Hazard. Agency compliance requires that the
baseplate be grounded or made inaccessible.
Fusing. Safety agency conditions of acceptability require
module input fusing. See
for recommended
fuse ratings.
IAM
+
–
IAM
C2
Diodes: 1N4148
[a]
C2: 470 pf / 500 V
100Ω
C2
VI-200
Driver
+IN
–IN
GATE
OUT
GATE
IN
VI-200
Booster
+IN
–IN
GATE
OUT
GATE
IN
VI-200
Booster
+IN
–IN
GATE
OUT
GATE
IN
VI-200
Driver
+IN
– IN
GATE
OUT
GATE
IN
VI-200
Driver
+IN
– IN
GATE
OUT
GATE
IN
+OUT
–OUT
–S
+S
TRIM
+OUT
–OUT
–S
+S
TRIM
+OUT
–OUT
–S
+S
TRIM
+OUT
–OUT
–S
+S
TRIM
+OUT
–OUT
–S
+S
TRIM
+IN
–IN
+OUT
–OUT
GATE IN
+IN
GATE OUT
–IN
PAR
[a]
For bus voltages greater than 75 V,
a 1N4006 diode should be used for the
diodes connected to the GATE IN pins.
+IN
–IN
+OUT
–OUT
GATE IN
+IN
GATE OUT
–IN
PAR
Figure 14–5 — Paralleling connections for the IAM
14. Input Attenuator Module (IAM / MI-IAM)
NOTE:
x,y capacitors not shown for clarity