beautypg.com

Emc considerations, Conducted noise vs. load – Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 21

background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 20 of 98

Apps. Eng. 800 927.9474

800 735.6200

9. EMC Considerations

C4

C1 = 100

µF

C2a – C2b = 4,700 pF

(Vicor Part # 01000)

C3a – C3b = 0.01 µF

(Vicor Part # 04872)

C4 = 2.2

µF

L1 = 3,000

µH

(Vicor Part # 31742)

Conditions

Light Load = 3 A

Nominal Load = 15 A

Full Load = 30 A

+IN

GATE

IN
GATE

OUT
–IN

+OUT

+S

TRIM

–S

–OUT

C2a

C1

C2b

C3b

C3a

L1

CM

3 Amp Load

15 Amp Load

30 Amp Load

Conducted Noise vs. Load

Figure 9–3 — Conducted input noise, with common-mode choke

Typical Vicor Module (VI-230-CV)

48 V Input, 5 V Output

Three common-mode chokes are offered as standard accessories.

NOTE: Common-mode filters may be common to one or
more modules, but only one should be used with modules
interconnected via GATE IN’s or, GATE OUT to GATE IN. As
an example, Driver / Booster arrays or Drivers with GATE IN’s
tied together to provide a common disable function.

Part

Inductance

Maximum

Resistance

Number

Each Winding

DC Current

Each Winding

31743

1,000 µH

12 Amperes

6.5 m

Ω

31742

3,000 µH

7 Amperes

18 m

Ω

31943

2,163 µH

1 Ampere

42 m

Ω

This manual is related to the following products: