beautypg.com

Ac input module (aim / mi-aim) – Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 37

background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 36 of 98

Apps. Eng. 800 927.9474

800 735.6200

D1

D2

D2

C2

C2

–OUT

–S

TRIM

+S

+OUT

+IN
GATE
IN
GATE
OUT

–IN

–OUT

–S

TRIM

+S

+OUT

+IN
GATE
IN
GATE
OUT
–IN

–OUT

–S

TRIM

+S

+OUT

+IN
GATE
IN
GATE
OUT
–IN

AIM

GATE OUT

PAR

GATE IN

+OUT

–OUT

L2/N

NC

NC

L1

D1, D2: 1N4148
C2: 470 pf / 500 V
D3: 1N4006

D1

Universal
AC In

Bussman Fuses,

PC Tron

0.47 µF

C1

[a]

Driver

Driver

Driver

[a]

Refer to Selecting Capacitors for

AIM Modules in the begining of this

Section. Refer to Typical application

for Vicor converter with AIM,

Figure 12–5, for recommended

external components.

D3

D3

D3

Y-capacitors not shown for clarity

Universal
AC In

AIM

GATE OUT

PAR

GATE IN

+OUT

–OUT

L2/N

NC

NC

L1

0.47 µF

–OUT

–S

TRIM

+S

+OUT

+IN

GATE
IN
GATE
OUT

–IN

VI-200/J00

Driver

Load

F2

0.01 µF (Two 4,700 pF)
Y-Rated Capacitors

0.01 µF (Two 4,700 pF)
Y-Rated Capacitors

0.01 µF Ceramic

0.01 µF Ceramic

C1

[a]

F1

[a]

Consult factory or refer to Selecting Capacitors for AIM Modules at the begining of this section.

Z1: MOV Part #30076

Fuse 1: 6.3A/250V (IEC 5X20 mm) Buss GDB-6.3 or 7 A / 250 V (3AG 1/4" x 1 1/4") Littlefuse 314-007

Fuse 2: For VI-X7X-XX — Buss PC-Tron 2.5 A (250 V)

For VI-X6X-XX — Buss PC-Tron 3 A (250 V)

For VI-X5X-XX — Buss PC-Tron 5 A

Z1

Figure 12–4 — AIM connection diagram, multiple Driver DC-DC converters

Figure 12–5 — Typical application for Vicor converter with AIM

12. AC Input Module (AIM / MI-AIM)

This manual is related to the following products: