9. EMC Considerations

C1 = 100 µF

C2a – C2b = 4,700 pF

(Vicor Part # 01000)

C3a – C3b = 0.01 µF

(Vicor Part # 04872)

C4 = 270 µF

(Tant.)

L1 = 200 nH

(Vicor Part # 30268)

Conditions

Light Load = 3 A

Nominal Load = 15 A

Full Load = 30 A

+IN

–IN

+OUT

–OUT

C3a

GATE

IN
GATE

OUT

+S

TRIM

–S

C2a

C1

C2b

C3b

C4

L1

Figure 9 –12 — Output noise, additional output inductor and capacitor (L-C Filter)

Output Ripple vs. Load

LC Output Filter

Typical Vicor Module (VI-230-CV) 48 V Input, 5 V Output

3 Amp Load

15 Amp Load