9. EMC Considerations

NOTE:

A low ESR capacitor should be used on the output, preferably tantalum.

3 Amp Load

15 Amp Load

30 Amp Load

+IN

–IN

+OUT

–OUT

C3a

GATE

IN
GATE

OUT

+S

TRIM

–S

C4

C2a

C1

C2b

C3b

C1 = 100 µF

C2a – C2b = 4,700 pF

(Vicor Part # 01000)

C3a – C3b = 0.01 µF

(Vicor Part # 04872)

C4 = 270 µF (Tant.)

Conditions

Light Load = 3 A

Nominal Load = 15 A

Full Load = 30 A

Figure 9–11 — Output noise, additional output capacitance

Output Ripple vs. Load

Addition of Output Capacitor

Typical Vicor Module (VI-230-CV) 48 V Input, 5 V Output