beautypg.com

Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 68

background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 67 of 98

Apps. Eng. 800 927.9474

800 735.6200

Example 3. Determine the maximum ambient temperature
of a 3-up FlatPAC delivering 12 V at 600 W in 500 LFM
with no additional conduction cooling to the chassis.

Maximum ambient temp. = T

max

θ

sa

x P

out

(

1

– 1

)

η

T

max

= 85°C

θ

sa

= 0.3°C/W

P

out

= 600 W

η = 85% = (0.85)

Maximum ambient temp. = 85 – 0.3 x 600

(

1

– 1

)

0.85

= 53°C

Example 4. Determine the temperature rise of a
150 W, VI-200 converter delivering 5 V at 132 W
with a Part #30090 heat sink in 200 LFM.

Temperature rise =

θ

sa

x P

out

(

1

– 1

)

η

θ

sa

= 1.1°C/W

P

out

= 132 W

η = 81% = (0.81)

Temperature rise = 1.1 x 132

(

1

– 1

)

0.81

= 34˚C Over ambient temperature

Example 5. Determine the baseplate to coldplate thermal
drop for an MI-200 converter delivering 5 V at 50 W with
a thermal pad.

Thermal drop =

θ

bs

x P

out

(

1

– 1

)

η

θ

bs

= 0.2°C/W

P

out

= 50 W

η = 81% = 0.81

Temperature rise = 0.2 x 50

(

1

– 1

)

0.81

= 2.34˚C

20. Thermal and Module Mounting Considerations

This manual is related to the following products: