Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 51 of 98

Apps. Eng. 800 927.9474

800 735.6200

FUSING INFORMATION

• 1.5 kW front end: 7 A / 250 V normal blow in all

three phases of the AC line (Bussman ABC-7 or
Littlefuse 314-007).

• 3 kW front end: 12 A / 250 V normal blow in all

three phases of the AC line (Bussman ABC-12 or
Littlefuse 314-012).

• 5 kW front end: 20 A / 250 V normal blow in all

three phases of the AC line (Bussman ABC-20).

ENVIRONMENTAL DATA

• Operating temperature (no load to full load):

–20˚C to +50˚C, free convection

• Non operating temperature: –40˚C to +80˚C

• Operating / non-operating humidity:

95% relative, non-condensing

ELECTRICAL DATA — AC LINE INPUT VOLTAGE
CONNECTIONS (PHASE TO PHASE)

• 3-phase delta (4 wire): 208 Vac (nominal) +20% / –10%.

Connect the three phases (L1, L2, L3) and GND (earth)
to the five terminal barrier block marked as such.

• 3-phase wye distribution (5-wire): 208 Vac (nominal)

+20% / –10%. Connect the three phases (L1, L2, L3),
N (neutral), and GND (earth) to the five terminal barrier
block marked as such.

• Line frequency: 47 – 440 Hz

DC OUTPUT CONNECTIONS AND MODULE ENABLE

A three terminal barrier block labeled Vdc–, Vdc+ and
MOD EN provides both the DC input enable and enable
control line for Vicor converters.

• Vdc–: Negative DC input terminal to all Vicor converters.

• Vdc+: Positive DC input terminal to all Vicor converters.

• MOD EN: Connect to the GATE IN terminal of all Driver

modules. This connection must be made to guarantee
proper enabling of the converter array on power-up and
proper shut down of the converter array on power loss,
loss of phase or output fault.

CAUTIONS

• This product is designed to operate with Vicor VI-x6x

Family (300 Vdc input) converters, Mega Modules and
the 300 Vin Maxi, Mini and Micro converters.

• This product is not intended for use with European

380 – 415 Vac three phase distribution.

• This product is an offline AC-DC power supply.

It is not isolated from the AC mains.

• Proper grounding is mandatory for safe operation.

16. Offline Front End