Opticon PHL 7200 User Manual User Manual
Page 78

OPTICON
User's manual
PHL-7000 series
3-15
Read 1 time
Redundancy = 0
Read 2 times
Redundancy = 1 (default)
Read 3 times
Redundancy = 2
Read 4 times
Redundancy = 3
Usually bar codes are printed black on white, but sometimes
white on black. These labels are called positive and negative
respectively. In case the ‘negative bar codes’ option has been
selected, positive labels may not be decoded or with difficulty.
Positive bar codes
Read black on white labels only
(default)
Negative bar codes
Read white on black labels only
Positive / Negative
bar codes
Positive and
negative bar codes
Read positive or negative labels
automatically.
Table 3-5 Read mode options descriptions
3.2.1.6 Advanced TAB
If enabled, this field can be used to send serial commands to the bar code reader.
Use this option only in case you want to access bar code reader features which are not
documented in this user’s manual, but are documented in Opticon’s Universal Menu Book.
If there is no need to make any other change to the bar code reader settings, do not use this
option. A maximum of 180 characters can be input. Default this option is disabled.
Figure 3-18 Command line options.