Opticon CRD 13 User Manual
Crd-13, Quick start guide
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700
/ email: [email protected]
U.S.A.
Opticon Inc.
tel: 800-636-0090
/ email: [email protected]
France
Opticon S.A.S.
tel: +33 (0)1-41461260
/ email: [email protected]
Germany
Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0
/ email: [email protected]
Italy
Opticon s.r.l.
tel: +39 (0)051-6321800
/ email: [email protected]
Spain
Opticon Sensores S.L.
tel: +34 (0)902-747469
/ email: [email protected]
Contact
Sweden
Opticon Sensors Nordic AB
tel: +46 (0)8-58548560
/ email: [email protected]
United Kingdom Opticon Limited
tel: +44 (0)1582-635100
/ email: [email protected]
Taiwan
Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Office
tel: +86 21-64480881
/ email: [email protected]
Australia
Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666
/ email: [email protected]
Brazil
Opticon Sensors Europe B.V., Latin American Office
tel: +55 11-5081 2088
/ email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Quick Start Guide
• The CRD-13 is a designated charging and communication cradle for the H-13.
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
Introduction
CRD-13
Copyright
©
2008 OPTO ELECTRONICS CO., LTD. All rights reserved.
■
Detailed View
Overview
■
CRD-13 Basic Specifications
No.
Part
Function
①
Power Supply
Status LED
Alerts users to the status of
power distribution from the
AC adapter to the cradle.
② Comm. Status LED
Alerts users to the status of
the IrDA data transmission.
③
IrDA
Communication
Window
The cradle communicates
with the designated portable
terminal through the IrDA
communication window.
④ Detection Switch
Terminal detection switch
to change the settings of
the power feeding section.
⑤
Portable Terminal
Charging
Terminals
Electrical terminals for power
distribution to the designated
portable terminal.
⑥ Guard Bar
To protect the USB, RS-232C
cables and DC jack.
⑦ Product Label
⑧ DIP Switches
DIP switches to configure the
settings of the CRD-13. Refer to
the DIP Switch Configuration
for details.
⑨ DC jack
DC6.0V power supply jack.
Please use the AC adapter.
⑩ USB Connector
Connector for USB interface.
⑪ RS-232C Connector Connector for RS-232C cable.
HCRD1359062-0-01
ご
使用にあたって
Memo
Using the Cradle
■
Charge Function
Parameter
Specifications
Physical
Features
Size
(H)64.9
×
(W)70.0
×
(D) 144.4mm
Weight
Approx. 125g
Control
Section
CPU
32bit RISC CPU
Internal
Memory
ROM : 256KB
RAM : 64KB
Comm.
Section
(H-13-CRD-13)
IrDA
※
1
IrDA Ver1.2 (physical layer only)
Baud rate: SiR : 9600 to 115.2kbps
FiR : 4Mbps
Comm.
Section
(CRD-13- Host)
RS-232C
※
2
Baud rate: 9600 bps
19.2, 38.4, 57.6,115.2 kbps
USB
Ver2.0 (Full-Speed)
Virtual COM
Power
Supply
Section
Main Power
Supply
AC Adapter : DC 6.0V, 2.0A
Current
Consumption
When communicating : 110mA or less
(DC 6.0V, when not charging)
Max: 1.7A or less
(when charging a portable terminal)
Charging Time Approx. 3 hours
Power Feed
Section
For Charging the
Portable Terminal
※
3
Output: DC 6.0V (Typ.)
Electrical terminals : + / -
Display
Section
LED
Power Supply : Red / Green
Data communication : Red / Green
Durability Operating Temp. -10 deg. C to 50 deg. C
Operating Humidity 25% to 85% (non-condensing)
Storage Temp. -20 deg. C to 60 deg. C
Storage Humidity 20% to 90% ( non-condensing)
Charging Temp. 0 deg. C to 40 deg. C
Shock
Endurance
Dropped once from each of 6
angles onto concrete from a height
of 75cm with no defects found.
・To avoid communication problems between the cradle
and a portable terminal, keep the IrDA window clean.
・ IrDA communication performance may decline due
to excessive ambient light (especially under strong
sunlight or inverted fluorescent light.)
Memo
Parameter
Specifications
AC
adapter Input
Power Voltage: AC 90 to 265V
Current Consumption : 0.5A max.
Output
Power Voltage: 5.7 to 6.3V
Maximum current: 2.0A max.
■
AC adapter Basic Specifications
※1
Baud Rate: Theoretical figure
※2
RS-232C baud rate synchronizes with IrDA baud rate.
※3
Can be switched ON/OFF using the detection switch.
❶
Charging starts as soon as the H-13 with the
provided battery (BTR0100) is placed into the cradle.
❷
The charging status LED for the H-13 turns solid
GREEN after the battery has finished charging
or when a fully charged battery is detected.
❸
Charging Time
Charging Time
Conditions
Approx. 3 hours Time needed to fully charge an empty battery.
* If you try to charge the battery pack when the
ambient temperature is outside the range of 0
to 40 degrees C, the cradle may stop charging
to protect the battery pack.
* Please clean the charging terminals of the
portable terminal on a regular basis.
* It is possible that the application program in the
terminal controls the terminal LED differently.
Memo
Status LEDs
Color
Function
Cradle LED
Green
Turn solid GREEN when a
portable terminal is placed
on the cradle.
Portable
Terminal LED
Red
Turn solid RED while the
battery is being charged.
Green Turn solid GREEN after the
battery has finished charging.
□
LED Notification
* Do not use a hub to connect the CRD-13 to
the host. Please use the designated USB cable
provided by Opticon.
memo
■
Supported Interface
Please use the RS-232C connector provided by Opticon.
RS-232C Interface
The CRD-13 supports USB2.0, Full Speed interface.
USB Interface
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or
converted to any electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or
indirect damages howsoever caused.
Cautions and Warnings
1. Handling Instructions
• Do not attempt to disassemble, modify or update this device.
• Do not use this device near combustible materials.
• Use only the AC adapter specified for this product.
• Do not drop this product or put heavy items on this product.
• Keep the device out of the reach of small children.
• Do not damage the AC adapter or power cable by bending, twisting, pulling, or heating. Do not use
them if they are seriously damaged.
• Do not store this device in an extremely cold or hot environment.
• Do not touch the AC adapter or power cable while your hands are wet.
• Do not insert foreign substances into the device.
• Do not charge the battery in temperatures less than 0 deg. C or greater than 40 deg. C.
• Keep the IrDA communication window clean to avoid communication problems.
• When cleaning this product, rub gently with either a soft dry cloth or a damp cloth with mild
detergent.
• Do not use this product in the following areas:
- In areas exposed to direct sunlight for long periods of time.
- Near water or other liquids, or in extremely high humidity.
- Near heat sources, such as radiators, heat registers, stoves, or other types of devices that produce heat.
(Please refer to the specification manual for details.)
No.
Item
Function
1
Cradle
Designated charging and communication cradle for the H-13.
2
AC/DC Adapter
Designated AC/DC adapter with a replaceable plug for the CRD-13.
3
RS-232C Cable
Designated RS-232C cable for the CRD-13.
4
USB Cable
Designated USB cable for the CRD-13.
5
Quick Start Guide
Provides product information and instruction guide.
Before Getting Started
■
What s in the Box
Confirm that you have the following items before getting started:
* The number of accessories may differ depending on the product specification.
Please contact the nearest dealer if accessories are damaged or missing.
■
DIP Switch (DIPSW) Configuration
Use the DIP switches on the bottom of the CRD-13
to configure the following settings.
DIP Switch Settings
Item
DIPSW
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
Baud Rate ○
○
○
Data Length
○
Parity bits
○
○
Stop bits
○
RFU
○
Baud Rate
Item
SW1
SW2
SW3
115.2K
OFF
OFF
OFF
57600
ON
OFF
OFF
38400
OFF
ON
OFF
19200
ON
ON
OFF
9600
OFF
OFF
ON
4M
ON
OFF
ON
Open
OFF
ON
ON
Auto configuration
ON
ON
ON
Data Length
Item
SW4
8 bits
OFF
7 bits
ON
Parity Bits
Item
SW5
SW6
No Parity
OFF
OFF
Odd Parity
ON
OFF
Even Parity
OFF
ON
Open
ON
ON
Stop Bits
Item
SW7
1 bit
OFF
2 bits
ON
Baud Rate: Auto configuration
Data Length: 8 bits, Parity Bits: No parity
Stop bits: 1 bit,
Default
Settings
Default Settings
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
* You need to turn the power ON again after
changing the DIP switch settings.
memo
②
H-13 LED
①
Cradle LED
Red: Charging
Green : Charging
complete
Green:Charging
theH-13