Opticon M5 User Manual
Quick start guide
M-500009062-0-00
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700
/ email: [email protected]
U.S.A.
Opticon Inc.
tel: 800-636-0090
/ email: [email protected]
France
Opticon S.A.S.
tel: +33 (0)1-41461260
/ email: [email protected]
Germany
Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0
/ email: [email protected]
Italy
Opticon s.r.l.
tel: +39 (0)051-6321800
/ email: [email protected]
Spain
Opticon Sensores S.L.
tel: +34 (0)902-747469
/ email: [email protected]
Contact
Sweden
Opticon Sensors Nordic AB
tel: +46 (0)8-58548560
/ email: [email protected]
United Kingdom Opticon Limited
tel: +44 (0)1582-635100
/ email: [email protected]
Taiwan
Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Office
tel: +86 21-64480881
/ email: [email protected]
Australia
Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666
/ email: [email protected]
Brazil
Opticon Sensors Europe B.V., Latin American Office
tel: +55 11-5081 2088
/ email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any
electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect
damages howsoever caused.
Precautions for Use
1. LED Safety
Do not stare into the LED s.
2. Handling Instructions
【
M-5
】
• Do not attempt to disassemble, modify or update this device.
• Do not use the scanner while operating machinery.
• Do not drop or put heavy items on this product or its cable.
• Do not pinch or forcibly bend the cable, especially at very low temperature.
• Do not insert foreign substances into the device.
• Do not use/leave this device:
- In areas exposed to direct sunlight for long periods of time
- In dusty environments
- In risk for an exposure to chemicals
- Near water or other liquids, as well as in extremely high humidity
- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat
- Near microwaves, medical devices, or RF-emitting devices
- In the reach of blinking lights such as CRT
• Do not use this product during a lightning storm.
【
AC/DC Adapter
】
• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
• This product may produce heat when in use, but it does not affect its performance.
• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.
• Do not plug in or out this product with wet hands.
• Unplug this product when it is not in use or when it is being cleaned.
Quick Start Guide
Introduction
M-5
Copyright
©
2009, Opticon All rights reserved.
Setting Menu Codes
The M-5 can be configured by reading the menu codes below. Read more about configuration options
(by Opticonfigure) on www.opticon.com.
■
Detailed View
Overview
■
M-5 Basic Specifications
Parameter
Specifications
Physical
Features
Size
(H)140.0
×
(W)92.0
×
(D)95.5 mm
Weight
Approx.295g (excluding the cable)
Operation
Section
Scan Confirmation Buzzer and 3 colors LED(Green/Blue/Orange)
Keys
2 keys (Trigger Switch/Mode Switch)
Interfaces RS-232C
9600bps
∼
115.2kbps
USB
Full-Speed 12Mbps(HID/VCP)
Hi-Power Bus-powered
Wedge
PS/2 Keyboard (Connect or disconnect the keyboard.)
Control
Section
ASIC
OEY-0603 CPU:ARM-1026EJ-S Core:160MHz
SDRAM
128Mbits(1M
×
4Banks
×
32Bits)
Flash ROM
16Mbits(1M
×
16Bits) Flash Memory
Scanning
Section
Light Source
Wavelength
8-AllnGaP Red LEDs(Omniscan Mode)/625nm
4-AllnGaP red LEDs (Mobile Mode)/633nm
Scanning Method WVGA(752 x 480 pixels) CMOS area sensor
Supported
Symbologies
(1D)
UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,
EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code
39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,
Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,
Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,
Korean Postal Authority code , GS1 DataBar, Postal Code
Supported
Symbologies
(2D)
PDF417,MicroPDF417,QR Code,MicroQR Code,Data
Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),
Aztec Code, EAN.UCC Composite bar code, Codablock F
Power
Supply
Section
Operating voltage 4.5 to 6.6V
Current
consumption
USB
RS-232C, Wedge
Peak
(when scanning and decoding)
420mA
400mA
Average
(when scanning and decoding)
280mA
(typ)
210mA
(typ)
Stand-by
140mA
(typ)
130mA
(typ)
Durability Operating Temp. 0 to 40 deg. C
Storage Temp.
−
40 to 70 deg. C
Operating Humidity 5 to 95
%
(non-condensing)
Storage Humidity 5 to 95
%
(non-condensing)
Ambient
Light
Immunity
Fluorescent
:
10,000lx or less
Incandescent lamp
:
10,000lx or less
Sunlight
:
50,000lx or less
(
*
1)
Dust-and-Drip Proof IP52
Static Electricity 15kV (no destruction)
Shock
Endurance
Dropped once from each of 5 angles onto
concrete floor from a height of 150cm with
no defects found. (Total 5 times)
No.
Part
Function
①
Optical Window
−
−
−
−
−
−
−
−
−
−
−
②
Trigger Switch
The trigger switch is used for the manual
scanning operation. A single aiming guide
will be activated in this mode.
③
Mode Switch
The mode switch toggles between Mobile phone
scanning mode and Normal scanning mode.
④
Indicator LED
Green LED light shows the scanning
operation has been successful.
Blue LED light shows when the scanner is
ready to scan.
⑤
Indicator LED While Mobile
phone scanning Mode
Orange LED light shows when the scanner
is ready for mobile code scanning.
⑥
Buzzer Holes
−
−
−
−
−
−
−
−
−
−
−
⑦
Screw Holes
Used to mount the scanner onto a base plate,
wall etc. using D4 (diameter: 4mm) screws.
①
⑦
②
③
⑥
⑤
④
Before Getting Started
No.
Item
Function
Notes
1
Scanner
An omnidirectional imaging scanner
−
−
−
−
−
−
−
−
−
−
−
2
Interface cable
A cable for connecting the scanner
Different for each interface spec.
3
Wedge branch cable
Y-cable: The cable that can be used to connect a keyboard
and the scanner's straight cable to a host computer.
Only for Wedge interface.
4
Connector cover
A cover used to fix the connection between the
Y-cable and the straight cable.
Only for M-5-WEDGE+PS package.
5
Instruction of connector cover An instruction manual for the connector cover
Only for M-5-WEDGE+PS package.
6
AC adapter
AC adapter with interchangeable plugs
Only for RS-232C and Wedge interface.
7
Interchangeable plugs
Plugs for different regions
Only for RS-232C and Wedge interface.
8
Quick start guide
This manual provides the basic product specification
and setup instructions.
−
−
−
−
−
−
−
−
−
−
−
■
What's in the Box
Confirm that you have the following items before getting started. Please note that the contents may differ
depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.
■
Various Scanning Modes
The following modes are available for different uses:
□ Normal scanning mode
A mode in which the scanner is configured optimally for general barcode
reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.
□ Mobile phone scanning mode
A special mode
― in which the lighting conditions are optimized for
reading barcodes,
― displayed on mobile devices such as a phone.
The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.
□ Single line scanning
While the trigger switch is pressed, the illumination LEDs turn on
and only one code can be read. The single line can read one target
code out of multiple printed codes in this mode.
Setting Menu Codes
(*1)Except Mobile phone scanning mode in each condition. Please note that scanning while the
LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.
Figure 1. Scanning mode diagram
Normal scanning
mode
Mobile phone
scanning mode
Mode Switch
Power
ON
Single line
scanning
Trigger
Switch
Finished Scanning
or Time-Out
■
Basic Specifications for Universal AC adapter
Parameter
Specifications
Physical
Features
Size
(H)75 x (W)47.5 x (D)28mm (excluding boss)
Cable Length
1.8m
Colour
Black
Input
Power Voltage AC 90V to 265V
Supply Current 500mA Max
Output
Power Voltage 5.7V to 6.3V
Maximum Current 2A Max
Environmental
Specification
Operating Temp. 0 to 40 deg. C
Operating Humidity 25 to 85% (non-condensing)
Storage Temp.
−
20 to 60 deg. C
Storage Humidity 20 to 90% (non-condensing)
Trigger
Switch
Finished Scanning
or Time-Out
: Default
Default Setting
■
Enable QR Code
(* Use this only when Disable QR Code is set in advance.)
Start / END: ZZ
Enable QR Code: BCD
Stop / END: ZZ
■
Back to default
Serial command :
U2, C01, SU, UB
"Normal scanning mode" or "Mobile phone scanning mode"
can be selected as primary mode when the scanner starts up.
Scanning Mode Setting
■
Normal scanning mode
Serial command :
E8Y
■
Mobile phone scanning mode
Serial command :
E8Z
Auto trigger ON / OFF can be set. When it is set to OFF, only
the trigger switch can be used to activate the scanner.
Auto Trigger Setting
■
Auto Trigger OFF
■
Auto Trigger ON
Serial command :
+I
Serial command :
+F
You can set the time that the scanner will try to read a code
after it is detected by the auto trigger. This can be set for Nor-
mal scanning mode and Mobile phone scanning mode .
For single line scanning, it can be set as the LED aiming time.
Read Time Setting
■
Normal scanning mode
Serial command :
Y0 (0.5s) Serial command : Y2 (2.0s)
Serial command :
Y1 (1.0s) Serial command : Y3 (3.0s)
■
Mobile phone scanning mode
Serial command :
E91 (1s)
Serial command :
E93 (3s)
Serial command :
E92 (2s)
Serial command :
E94 (4s)
■
Single line scanning
Serial command :
E8V (1s)
Serial command :
E8X (5s)
Serial command :
E8W (3s)
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
The time that a code will not be read after it is read successful
once can be set. This can prevent the double read of a code.
Multiple read reset time Setting
■
Multiple read reset time
Serial command :
AJ (200ms)
Serial command :
AK (300ms) Serial command : E9I (800ms)
Serial command :
E9H (700ms)
Serial command :
AL (400ms)
Serial command :
AN (600ms)
Serial command :
E9J (900ms)
Serial command :
AG (Infinity)
Serial command :
AM (500ms) Serial command : E8T (1s)