Stabil-trak, Stabil-trak™ system and boom interlock system – SkyTrak 6036 Service Manual User Manual
Page 242
![background image](/manuals/546129/242/background.png)
Stabil-TRAK™
System and Boom Interlock System
10-14
6036, 6042, 8042, 10042, 10054
10.8
STABIL-TRAK™
BOOM
INTERLOCK
ELECTRICAL CIRCUIT OPERATION AND
TROUBLESHOOTING (6042/8042/10042)
Note: Before using the 6042, 8042 and 10042 Stabil-
TRAK System Troubleshooting chart and diagrams,
complete the Section 10.7.2, “Stabil-TRAK™
Test Procedures,” to determine what part of the system
is not functioning properly.
Definitions:
PB = Park Brake
SB = Service Brake
DE = De-energized
E = Energized
C = Closed
O = Open
6042, 8042 and 10042 Stabil-TRAK™
System
Troubleshooting
FREE PIVOT
MODE
SLOW PIVOT
MODE
LOCKED
MODE
Refer to Section , “6042, 8042
and 10042 Stabil-TRAK™
Refer to Section , “6042, 8042
Refer to Section , “6042, 8042
and 10042 Stabil-TRAK™
Elec-
trical Circuit LOCKED MODE.”
Machine
Conditions
Switch/
Relay
Solenoid
Ignition On
Boom Below 40°
Boom Retracted
PB & SB Released
Trans. in Forward or Reverse
Ignition On
Boom Above 40°
Boom Extended
PB & SB Released
Trans. in Forward or Reverse
Ignition On
Boom Above 40°
Boom Extended
PB & SB Applied
& Trans. in Neutral
Solenoid 12A
E
DE
DE
Solenoid 12B
E
DE
DE
Solenoid 3
DE
DE
E
Solenoid 4A
DE
E
DE
Solenoid 4B
DE
E
DE
Boom Angle Sensor
C
O
O
Boom Switch Relay
E
DE
DE
Stabilizer Lock Relay
DE
DE
E
Stabilizer Light
OFF (DE)
OFF (DE)
ON (E)
Ignition Switch
C
C
C
Park Brake Switch
O
O
C
Service Brake Switch
O
O
C
Secondary Function Manifold
Park Brake Solenoids
E
E
DE
Park Brake Disengage Relay
E
E
DE
Neutral Start Relay
DE
DE
E