SkyTrak 6036 Service Manual User Manual
Page 222
![background image](/manuals/546129/222/background.png)
Electrical System
9-34
6036, 6042, 8042, 10042, 10054
422
111
2
Amber
Coolant Level Coolant Level - Data Erratic, Intermittent, or Incorrect
2448
111
17
Amber/
Blinking
Coolant Level
Coolant Level—Data Valid But Below Normal Operating
Range - Least Severe Level
449
157
0
Red
Injector
Metering Rail
1 Pressure
Fuel Pressure High—Data Valid but Above Normal
Operational
Range—Moderately Severe Level
451
157
3
Amber
Injector
Metering Rail
1 Pressure
Injector Metering Rail #1 Pressure Sensor Circuit—Voltage
Above Normal, or Shorted to High Source
452
157
4
Amber
Injector
Metering Rail
1 Pressure
Injector Metering Rail #1 Pressure Sensor Circuit—Voltage
Below Normal, or Shorted to Low Source
553
157
16
Amber
Injector
Metering Rail
1 Pressure
Injector Metering Rail #1 Pressure High—Data Valid but Above
Normal Operational Range—Moderately Severe Level
559
157
18
Amber
Injector
Metering Rail
1 Pressure
Injector Metering Rail #1 Pressure Low—Data Valid but Below
Normal Operational Range—Moderately Severe Level
1911
157
0
Amber
Injector
Metering Rail
Injector Metering Rail 1 Pressure—Data Valid but Above
Normal Operational Range—Most Severe Level
2249
157
1
Amber
Injector
Metering Rail
1 Pressure
Injector Metering Rail 1 Pressure—Data Valid but Below
Normal Operational Range—Most Severe Level
441
168
18
Amber
Electrical
Potential
(Voltage)
Battery #1 Voltage Low—Data Valid but Below Normal
Operational Range—Moderately Severe Level
442
168
16
Amber
Electrical
Potential
(Voltage)
Battery #1 Voltage High—Data Valid but Above Normal
Operational Range—Moderately Severe Level
234
190
0
Red
Engine Speed
Engine Speed High - Data Valid but Above Normal Operational
Range—Most Severe Level
689
190
2
Amber
Engine Speed
Primary Engine Speed Sensor Error—Data Erratic,
Intermittent, or Incorrect
2321
190
2
None
Engine Speed
Engine Speed /Position Sensor #1—Data Erratic, Intermittent,
or Incorrect
2468
190
0
Engine Crankshaft Speed/Position—Data Valid But Above
Normal Operating Range—Moderately Severe Level
349
191
16
Amber
Transmission
Output Shaft
Speed
Transmission Output Shaft Speed - Data Valid but Above
Normal Operational Range - Moderately Severe Level
Fault
Code
SPN
Code
FMI
Code
LAMP
Area
Description
Diagnostic Description