SkyTrak 6036 Service Manual User Manual
Page 221
![background image](/manuals/546129/221/background.png)
9-33
6036, 6042, 8042, 10042, 10054
Electrical System
153
105
3
Amber
Intake
Manifold #1
Temp
Intake Manifold Air Temperature Sensor Circuit—Voltage
Above Normal, or Shorted to High Source
154
105
4
Amber
Intake
Manifold #1
Temp
Intake Manifold Air Temperature Sensor Circuit—Voltage
Below Normal, or Shorted to Low Source
155
105
0
Red
Intake
Manifold #1
Temp
Intake Manifold Air Temperature High—Data Valid but Above
Normal Operational Range—Most Severe Level
488
105
16
Amber
Intake
Manifold
Intake Manifold 1Temperature—Data Valid but Above Normal
Operational Range—Moderately Severe Level
221
108
3
Amber
Barometric
Pressure
Barometric Pressure Sensor Circuit —Voltage Above Normal,
or Shorted to High Source
222
108
4
Amber
Barometric
Pressure
Barometric Pressure Sensor Circuit—Voltage Below Normal,
or Shorted to Low Source
295
108
2
Amber
Barometric
Pressure
Barometric Pressure Sensor Circuit—Data Erratic, Intermittent,
or Incorrect
144
110
3
Amber
Engine
Coolant
Temperature
Coolant Temperature Sensor Circuit—Voltage Above Normal,
or Shorted to High Source
145
110
4
Amber
Engine
Coolant
Temperature
Coolant Temperature Sensor Circuit—Voltage Below Normal,
or Shorted to Low Source
146
110
16
Amber
Engine
Coolant
Temperature
Coolant Temperature High—Data Valid but Above Normal
Operational Range—Moderately Severe Level
151
110
0
Red
Engine
Coolant
Temperature
Coolant Temperature Low—Data Valid but Above Normal
Operational Range—Most Severe Level
2646
110
31
Amber
Not Available
Engine Coolant Temperature—Condition Exists
195
111
3
Amber
Coolant Level
Coolant Level Sensor Circuit—Voltage Above Normal, or
Shorted to High Source
196
111
4
Amber
Coolant Level
Coolant Level Sensor Circuit—Voltage Below Normal, or
Shorted to Low Source
197
111
18
Amber
Coolant Level
Coolant Level—Data Valid but Below Normal Operational
Range —Moderately Severe Level
235
111
1
Red
Coolant Level
Coolant Level Low—Data Valid but Below Normal Operational
Range—Most Severe Level
Fault
Code
SPN
Code
FMI
Code
LAMP
Area
Description
Diagnostic Description