beautypg.com

SkyTrak 6036 Service Manual User Manual

Page 225

background image

9-37

6036, 6042, 8042, 10042, 10054

Electrical System

2195

703

14

Auxiliary Equipment Sensor Input 3 Engine Protection
Critical— Special Instructions

731

723

7

Amber

Engine Speed

Sensor #2

Engine Speed/Position #2 Mechanical Misalignment Between
Camshaft and Crankshaft Sensors—Mechanical System
Not Responding Properly or Out of Adjustment

778

723

2

Amber

Engine Speed

Sensor #2

Engine Speed Sensor (Camshaft) Error—Data Erratic,
Intermittent, or Incorrect

2322

723

2

None

Engine Speed

Sensor #2

Engine Speed /Position Sensor #2—Data Erratic, Intermittent,
or Incorrect

2555

729

3

Amber

Inlet Air

Heater Driver

#1

Intake Air Heater #1 Circuit—Voltage Above Normal, or
Shorted to High Source

2556

729

4

Amber

Inlet Air

Heater Driver

#1

Intake Air Heater #1 Circuit—Voltage Below Normal, or
Shorted to Low Source

133

974

3

Red

Remote

Accelerator

Remote Accelerator Pedal or Lever Position Sensor Circuit—
Voltage Above Normal, or Shorted to High Source

134

974

4

Red

Remote

Accelerator

Remote Accelerator Pedal or Lever Position Sensor Circuit—
Voltage Below Normal, or Shorted to Low Source

288

974

19

Red

Remote

Accelerator

SAE J1939 Multiplexing Remote Accelerator Pedal or Lever
Data Error—Received Network Data In Error

697

1136

3

Amber

Sensor Circuit

- Voltage

ECM Internal Temperature Sensor Circuit—Voltage Above
Normal, or Shorted to High Source

698

1136

4

Amber

Sensor

Circuit—

Voltage

ECM Internal Temperature Sensor Circuit—Voltage Below
Normal, or Shorted to Low Source

691

1172

3

Amber

Turbocharger

#1Compressor

Inlet

Temperature

Turbocharger 1 Compressor Inlet Temperature Circuit—
Voltage Above Normal, or Shorted to High Source

3925

1188

2

Amber

Engine Turbocharger Wastegate Actuator 1 Position—Data
erratic, intermittent or incorrect

2373

1209

3

Amber

Exhaust Gas

Pressure

Exhaust Gas Pressure Sensor Circuit—Voltage Above
Normal, or Shorted to High Source

2374

1209

4

Amber

Exhaust Gas

Pressure

Exhaust Gas Pressure Sensor Circuit—Voltage Below Normal,
or Shorted to Low Source

2554

1209

2

Amber

Not Available

Exhaust Gas Pressure—Data Erratic, Intermittent or Incorrect

Fault

Code

SPN

Code

FMI

Code

LAMP

Area

Description

Diagnostic Description

This manual is related to the following products: