SkyTrak 6036 Service Manual User Manual
Page 225
9-37
6036, 6042, 8042, 10042, 10054
Electrical System
2195
703
14
Auxiliary Equipment Sensor Input 3 Engine Protection
Critical— Special Instructions
731
723
7
Amber
Engine Speed
Sensor #2
Engine Speed/Position #2 Mechanical Misalignment Between
Camshaft and Crankshaft Sensors—Mechanical System
Not Responding Properly or Out of Adjustment
778
723
2
Amber
Engine Speed
Sensor #2
Engine Speed Sensor (Camshaft) Error—Data Erratic,
Intermittent, or Incorrect
2322
723
2
None
Engine Speed
Sensor #2
Engine Speed /Position Sensor #2—Data Erratic, Intermittent,
or Incorrect
2555
729
3
Amber
Inlet Air
Heater Driver
#1
Intake Air Heater #1 Circuit—Voltage Above Normal, or
Shorted to High Source
2556
729
4
Amber
Inlet Air
Heater Driver
#1
Intake Air Heater #1 Circuit—Voltage Below Normal, or
Shorted to Low Source
133
974
3
Red
Remote
Accelerator
Remote Accelerator Pedal or Lever Position Sensor Circuit—
Voltage Above Normal, or Shorted to High Source
134
974
4
Red
Remote
Accelerator
Remote Accelerator Pedal or Lever Position Sensor Circuit—
Voltage Below Normal, or Shorted to Low Source
288
974
19
Red
Remote
Accelerator
SAE J1939 Multiplexing Remote Accelerator Pedal or Lever
Data Error—Received Network Data In Error
697
1136
3
Amber
Sensor Circuit
- Voltage
ECM Internal Temperature Sensor Circuit—Voltage Above
Normal, or Shorted to High Source
698
1136
4
Amber
Sensor
Circuit—
Voltage
ECM Internal Temperature Sensor Circuit—Voltage Below
Normal, or Shorted to Low Source
691
1172
3
Amber
Turbocharger
#1Compressor
Inlet
Temperature
Turbocharger 1 Compressor Inlet Temperature Circuit—
Voltage Above Normal, or Shorted to High Source
3925
1188
2
Amber
Engine Turbocharger Wastegate Actuator 1 Position—Data
erratic, intermittent or incorrect
2373
1209
3
Amber
Exhaust Gas
Pressure
Exhaust Gas Pressure Sensor Circuit—Voltage Above
Normal, or Shorted to High Source
2374
1209
4
Amber
Exhaust Gas
Pressure
Exhaust Gas Pressure Sensor Circuit—Voltage Below Normal,
or Shorted to Low Source
2554
1209
2
Amber
Not Available
Exhaust Gas Pressure—Data Erratic, Intermittent or Incorrect
Fault
Code
SPN
Code
FMI
Code
LAMP
Area
Description
Diagnostic Description