Troubleshooting

80

Troubleshooting

Table 7.1 General Problems (Continued)

Problem

Suggested Solution

Firmware
Initializing...

appears and remains on the
screen.

Make sure that TERMPWR is being properly
provided to each peripheral device populated
channel.

Make sure that each end of the channel chain is
properly terminated using the recommended
terminator type for the peripheral device. The
channel is automatically terminated at the RAID
Controller Kit-G card if only one cable is
connected to a channel.

Make sure (on a channel basis) only two types
of cables are connected at any one time.

Make sure that the RAID Controller Kit-G
controller is properly seated in the PCI slot.

What SCSI IDs can a non-hard
disk device have and what is
maximum number allowed per
adapter?

Non-hard disk devices can accommodate only
SCSI IDs 1, 2, 3, 4, 5 or 6, regardless of the
channel used. A maximum of six non-hard disk
devices are supported per RAID Controller Kit-
G adapter.