beautypg.com

Step 7 connect scsi cables – Toshiba Magnia 560S User Manual

Page 89

background image

Installation Steps

Hardware Installation

71

Step 7 Connect SCSI Cables

Connect SCSI cables to SCSI devices. RAID Controller Kit-G provides two SCSI
connectors: J1, the SCSI channel internal high-density 68-pin connector for Wide (16-
bit) SCSI and J7, the SCSI channel external very high-density 68-pin connector.

Connect SCSI Devices

When connecting SCSI devices, use the procedure in Table 6.8.

Table 6.8 Procedure for Connecting SCSI Devices

Step

Action

1

Disable termination on any SCSI device that does not sit at the end of the
SCSI bus.

2

Configure all SCSI devices to supply TermPWR.

3

Set proper target IDs (TIDs) for all SCSI devices.

4

The cable length can be up to 20 meters.

Cable Suggestions

System throughput problems can occur if SCSI cable use is not maximized. You
should:

You can use cables up to 12 meters for LVD devices.

For single-ended SCSI devices, use the shortest SCSI cables.

Use active termination.

Avoid clustering the cable nodes.

Cable stub length should be no more than 0.1 meter (4 inches.)

Route SCSI cables carefully.

Use high impedance cables.

Use flat cables for inside the enclosure, and round, shielded cables for outside of the
enclosure.

Ribbon cables have fairly good cross-talk rejection characteristics.