Hardware installation, Requirements, Checklist – Toshiba Magnia 560S User Manual
Page 77
Hardware Installation
Hardware Installation
59
Hardware Installation
Requirements
You must have the following for hardware installation:
•
A RAID Controller Kit-G controller
•
A host computer with an available PCI expansion slot
•
The RAID Controller Kit-G Installation CD
•
The necessary SCSI cables and terminators (This depends on the number and type
of SCSI devices to be attached.)
•
An uninterruptible power supply (UPS) for the entire system
•
Ultra320, Ultra, Fast SCSI 2 or Wide SCSI hard disk drives
Optional Equipment
You may also want to install SCSI cables that connect RAID Controller Kit-G to
external SCSI devices.
Checklist
Table 6.1 provides a checklist of the steps for installation.
Table 6.1 Checklist for Installation
Check
Step
Action
1
Turn all power off to the server and all hard disk drives, enclosures,
and system, components.
2
Prepare the host system. See the host system technical
documentation.
3
Determine the SCSI ID and SCSI termination requirements.
4
Make sure the jumper settings on the RAID Controller Kit-G
controller are correct.
5
Install the MegaRAID in the server and attach the SCSI cables and
terminators as needed. Make sure pin 1 on the cable matches pin 1
on the connector. Make sure that the SCSI cables you use conform
to all SCSI specifications.
6
Perform a safety check. Make sure all cables are properly attached.
Make sure the MegaRAID card is properly installed. Turn power
on after completing the safety check.
7
Install and configure the MegaRAID software utilities and drivers.