Other potential problems – Toshiba Magnia 560S User Manual
Page 103
Troubleshooting
Troubleshooting
85
Other Potential Problems
Table 7.5 lists other items that might cause problems.
Table 7.5 Other Potential Problems
Topic
Information
DOS ASPI
MEGASPI.SYS, the MegaRAID DOS ASPI manager,
uses 6 KB of system memory once it is loaded.
CD drives under DOS
At this time, copied CDs are not accessible from DOS
even after loading MEGASPI.SYS and
MEGACDR.SYS.
Physical drive errors
To display the
MegaRAID Manager
Media Error and
Other Error options, press
drive under the Physical Drive menu, selected from the
Objects menu. A Media Error is an error that occurred
while actually transferring data. An Other Error is an error
that occurs at the hardware level because of a device
failure, poor cabling, bad termination, signal loss, etc.
Virtual sizing
The virtual sizing option enables RAID expansion.
Virtual sizing must be enabled to increase the size of a
logical drive or add a physical drive to an existing logical
drive. Run
MegaRAID Manager
by pressing
to enable virtual sizing. Select the Objects menu, then
select the Logical Drive menu. Select View/Update
Parameters. Set Virtual Sizing to Enabled.
BSD Unix
We do not provide a driver for BSDI Unix. RAID
Controller Kit-G does not support BSDI Unix.
Multiple LUNs
RAID Controller Kit-G supports one LUN per each target
ID. No multiple LUN devices are supported.
RAID Controller Kit-
G power requirements
The maximum RAID Controller Kit-G power
requirements are 15 watts at 5V and 3 Amps.