Toshiba Magnia 560S User Manual
Page 234
Event Types
216
MegaRAID Service Monitor
Table C.2 Valid Event Types (Continued)
Event Types
Severity Level
Log Messages
Device slot ID number
changed
Warning
Device Slot # ID=#:
The associated physical drive ID has
changed.
Physical Drive # is Removed/Power
Off. Physical Drive # is Added/Power
On.
These messages are not currently
available.
Battery Status:
Warning
Battery Backup Module is Missing
Warning
Battery Backup Module present but
Battery Backup Pack is Missing
Battery backup
module/pack
missing or added
Informational
Battery Backup/Pack present
Warning
Battery Temperature OUT OF
RANGE
Battery temperature
out of range or back to
normal
Informational
Battery Temperature GOOD
Warning
Battery Voltage LOW
Battery Voltage
low or normal
Informational
Battery Voltage GOOD
Warning
Battery Fast Charging IN PROGRESS
Warning
Battery Fast Charging FAILED
Battery fast
charging in
progress/failed/
completed
Informational
Battery Fast Charging COMPLETED
Number of battery
charge cycles
Informational
"No of Charge Cycles = ??"
Warning
Physical drive is Removed/Powered
Off
Since the monitor
program scans the bus
periodically, it checks
for devices and
compares with the
previous results. If not
a match, it logs
messages.
Warning
Physical drive is Added/Powered On
The Power On/Off feature is not
implemented in the current version
because the monitor program only
scans the bus once at the beginning of
program execution. It cannot detect
later device changes.