Brocade Communications Systems Brocade ICX 6650 User Manual
Page 73

Brocade ICX 6650 Administration Guide
55
53-1002600-01
Using SNMP to upgrade software
3
NOTE
The syntax shown in this section assumes that you have installed HP OpenView in the “/usr”
directory.
NOTE
Brocade recommends that you make a backup copy of the startup-config file before you upgrade the
software. If you need to run an older release, you will need to use the backup copy of the
startup-config file.
1. Configure a read-write community string on the Brocade device, if one is not already
configured. To configure a read-write community string, enter the following command from the
global CONFIG level of the CLI.
snmp-server community
where
2. On the Brocade device, enter the following command from the global CONFIG level of the CLI.
no snmp-server pw-check
This command disables password checking for SNMP set requests. If a third-party SNMP
management application does not add a password to the password field when it sends SNMP
set requests to a Brocade device, by default the Brocade device rejects the request.
3. From the command prompt in the UNIX shell, enter the following command.
/usr/OV/bin/snmpset -c
ipaddress
1.3.6.1.4.1.1991.1.1.2.1.7.0 integer
where
20 – Download the flash code into the primary flash area.
22 – Download the flash code into the secondary flash area.