beautypg.com

Appendix a, Syslog messages, Appendix – Brocade Communications Systems Brocade ICX 6650 User Manual

Page 291

background image

Brocade ICX 6650 Administration Guide

273

53-1002600-01

Appendix

A

Syslog messages

Table 57

lists all of the Syslog messages. Note that some of the messages apply only to Layer 3

Switches.

NOTE

This chapter does not list Syslog messages that can be displayed when a debug option is enabled.

The messages are listed by message level, in the following order, then by message type:

Emergencies (none)

Alerts

Critical

Errors

Warnings

Notifications

Informational

Debugging

TABLE 57

Brocade Syslog messages

Message level

Message

Explanation

Alert

modules and 1 power
supply, need more power supply!!

Indicates that the chassis needs more
power supplies to run the modules in the
chassis.
The parameter indicates
the number of modules in the chassis.

Alert

Fan , , failed

A fan has failed.
The is the fan number.
The describes where the failed
fan is in the chassis.

Alert

MAC Authentication failed for
on

RADIUS authentication was successful for
the specified on the
specified ; however, the VLAN
returned in the RADIUS Access-Accept
message did not refer to a valid VLAN or
VLAN ID on the Brocade device. This is
treated as an authentication failure.

Alert

MAC Authentication failed for
on (Invalid User)

RADIUS authentication failed for the
specified on the specified
because the MAC address sent
to the RADIUS server was not found in the
RADIUS server users database.